621510
13
Zoom out
Zoom in
Vorherige Seite
1/51
Nächste Seite
Behaving in Case of Emergency
Provide first aid corresponding to seriousness of injuries
and seek qualified medical advice as soon as possible.
Put the injured person to peace and protect him/her
against other injuries.
Device Use as Designed
For blowing and works with compressed air, in clay-
modelling, for airbrush painting of walls, airbrush
varnishing works, tyre pressure rating, etc.
Residual Dangers
Direct electric contact
A faulty cable or faulty connector plug may lead to a
fatal accident caused by electric current.
Have always the faulty cables and connector plugs
replaced at a specialist. Use the device at a connector
equipped with current protector (RCD) only.
Indirect electric contact
Injury by parts of the machine that are live or by
faulty constructional elements of the machine.
Always pull the connector plug out of socket at
maintenance works. Operate with current protector only.
Insufficient local lighting
Insufficient lighting represents a high safety risk.
Always ensure sufficient lighting at work with this device.
Disposal
Instructions for disposal result from icons on the device,
or more precisely, on the package. Description of each
meaning can be found in the “Marking“ chapter.
Operating Staff Requirements
The operating staff must thoroughly read the operating
instructions before using the machine.
Qualification
No additional qualification is needed for using the device
apart from detailed training by a person with expert
knowledge.
Minimum Age
The device may only be operated by persons that have
reached 16 years of age.
An exception includes device use by juveniles within job
preparation for purpose of reaching skills under
instructor's supervision.
Training
Appropriate training is only needed for device use. No
special training is necessary.
Transportation and Storage
If the device is stored for a longer period of time it
needs to be thoroughly cleaned and stored so that it
was not accessible to unauthorised persons.
The compressor must never be stored or transported
laying or under pressure!
Pressure in the air jet may be reduced at
compressed air cooling.
Assembly / First Putting into Operation
If the compressor is supplied without wheels assemble it with a
screw wrench according to pic. 2. The sequence of screws, nuts
and washers is evident from pic. 2. In case of need, a rubber foot
also needs to be screwed on. Jointing materials, such as screws,
nuts, etc. are included in the supply.
Transport stopper of the oil tank needs to be
exchanged for throat for oil adding and correct oil level
needs to be ensured (see the "Handling Throat for Oil
Adding and Oil Level Inspection" chapter) before putting the
compressor into operation)
Check the oil level at every startup!!!
Handling
Pull the connector plug out of socket before each
maintenance, arrangement and adjustment of the
compressor.
Working Pressure Adjustment
The working pressure may be adjusted very easily: By
turning the knob (2) in the + direction the working
pressure increases. By turning the knob in the – direction
the working pressure reduces. The working pressure
may be locked by tightening the snap ring.
The compressor is equipped with an automatic safety
valve releasing pressure at overpressure. You may
release pressure from the air jet manually by pulling
the valve ring (10).
ATTENTION:
Realise the amount of compressed air you will need from the
device! The pressure itself, however, is NOT decisive for perfect
and sufficient operation. Short switching the compressor on after
a long break without use is common!
Have any repairs executed exclusively at qualified specialists.
Turn the compressor never about the power,
otherwise no discharge of the unit is done. Without
discharge, the electric motor through the back pressure
damage!
Throat for Oil Adding and Oil Level Inspection
Transport stopper needs to be exchanged for throat
for oil adding and correct oil level needs to be ensured
before putting the compressor into operation.
Check the oil level at every startup!!!
Oil change
Since arriving on the piston can chip, it is absolutely
necessary after the first 10 hours of operation to carry out an
oil change. We recommend that you are our compressor
(SKU: 40056). Later, depending on the operation of the
compressor, all 100 to 200 hours of operation an oil change
place. In order to carry out oil changes, open the drain screw
(16) and begin the process of waste oil in a suitable
container.
13

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Gude 300-10-50 DG 14 TLG 71126 wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info