properly. Abide by all the safety measures stated in
the service manual. Act responsibly toward third
parties.
The operator is responsible for accidents or risks to
third parties.
In case of any doubts about connection and operati-
on refer please to our customer center
Technical Data
Electric generatorGSE 3700 RS GSE 4700 RS GSE 6700
Art. No .........................................................................................40643 ....................................... 40631 ........................................40635
Service connection ...................................2 x 230 V ~ 50 Hz ..................2 x 230 V ~ 50 Hz .................2 x 230 V ~ 50 Hz
1 x 400 V ( CEE 16 A )
Rated current ................................................................... 10 A ...................................... 15,7 A ........................................19,6 A
7,2 A
Constant power .....................................2500 W / 3000 VA .................3500 W / 4100 VA ..... 230 V 4500 W / 5300 VA
400 V 5000 W / 5900 VA
Rated power ............................................2800 W / 3300 VA .................4000 W / 4700 VA ..... 230 V 5000 W / 5900 VA
400 V 5500 W / 6500 VA
Power class ..........................................................................G 1 .............................................G 1 ............................................. G 1
Power factor ........................................................................0,9 ........................................... 0,85 ............................................0,85
Rated speed..........................................................3180 min
-1
............................... 3180 min
-1
...............................3180 min
-1
tank capacity (Petrol) ......................................................12 l .............................................25 l .............................................25 l
Consumption at half load .........................................1,3 l/h .......................................2,3 l/h ........................................3,3 l/h
Oil amount .........................................................................0,6 l .............................................1,1l .............................................1,1l
Weight ...........................................................................41,5 kg .....................................65,7 kg ......................................84,6 kg
Dimensions L x B x H ......................570 x 435 x 525 mm ............670 x 515 x 510 mm ............720 x 530 x 655 mm
Degree of protection ...............................................IP 23 M .....................................IP 23 M ..................................... IP 23 M
Noise and Vibration Information
Sound pressure level L
PA
...........................................74,26 dB (A) ............................74,51 dB (A) ............................76,00 dB (A)
Uncertainty K = ...............................................................1,55 dB (A) .................................1,0 dB (A) ...............................0,40 dB (A)
Measured sound power level L
WA
1)
......................95,81 dB (A) ................................95,51
dB (A) ............................95,43 dB (A)
Guaranteed sound power level L
WA
1)
........................96 dB (A) ........................................96 dB (A) ........................................96 dB (A)
Wear ear protectors!
Measured according to
1)
2000/14/EG
Speci ed Conditions Of Use
This power unit has solely been designed for the
operation of electrical equipment with a maximum
power within the power unit performance data.
Higher starting current of induction appliances must
be considered.
The unit has been designed for operation of common
e ective and induction appliances such as light
chains, electric hand tools (drills, electric chain saws,
compressors).
When connected to a stationary device such
as heating, electrical power, air conditioning
equipment or for the supply of mobile homes, it
is necessary to contact a professional electrician
and heating manufacturer as far as connection
and grounding is concerned.
Not observing general regulations in force and
instructions from this manual does not make the
manufacturer liable for damages.
Protective equipment „Protective separation with
potential balancing“ is provided and integrated by
Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.
Art des Missbrauchs:
Forenregeln
Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:
Lesen Sie zuerst die Anleitung;
Schauen Sie nach, ob die Frage bereits gestellt wurde;
Stellen Sie die Frage so deutlich wie nur einigermaßen möglich;
Erwähnen Sie was Sie bereits versucht haben um das Problem zu lösen;
Ist Ihr Problem von einem Besucher gelöst dann lassen Sie ihn / sie wissen in diesem Forum;
Falls Sie reagieren möchten, so verwenden Sie bitte das Antworten- Formular;
Da ihre Frage für alle Besucher sichtbar ist, sollten Sie lieber keine persönliche Daten erwähnen.
Neu registrieren
Registrieren auf E - Mails für Gude GSE 6700 40635 wenn:
neue Frage gestellt werden
neue Handbücher vorhanden sind
Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.
Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.
Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.
Ihre Frage wurde zu diesem Forum hinzugefügt
Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.