26
ENGLISH
GB
Read and understand the
operating instructions before using
the appliance. Familiarise with the
control elements and how to use the appliance
properly. Abide by all the safety measures stated in
the service manual. Act responsibly toward third
parties.
The operator is responsible for accidents or risks to
third parties.
In case of any doubts about connection and operati-
on refer please to our customer center
Technical Data
Electric generator GSE 3700 RS GSE 4700 RS GSE 6700
Art. No .........................................................................................40643 ....................................... 40631 ........................................40635
Service connection ................................... 2 x 230 V ~ 50 Hz ..................2 x 230 V ~ 50 Hz ................. 2 x 230 V ~ 50 Hz
1 x 400 V ( CEE 16 A )
Rated current ................................................................... 10 A ...................................... 15,7 A ........................................19,6 A
7,2 A
Constant power .....................................2500 W / 3000 VA .................3500 W / 4100 VA ..... 230 V 4500 W / 5300 VA
400 V 5000 W / 5900 VA
Rated power ............................................2800 W / 3300 VA .................4000 W / 4700 VA ..... 230 V 5000 W / 5900 VA
400 V 5500 W / 6500 VA
Power class ..........................................................................G 1 ............................................. G 1 ............................................. G 1
Power factor ........................................................................ 0,9 ........................................... 0,85 ............................................0,85
Contents .....................................................................207 ccm ...................................270 ccm ................................... 389 ccm
Engine type ..........................................1-cylinder 4-stroke .............. 1-cylinder 4-stroke .............. 1-cylinder 4-stroke
Motor output ............................................... 4,8 kW / 6,5 PS .......................... 6,6 kW / 9 PS ........................9,5 kW / 13 PS
Rated speed.......................................................... 3180 min
-1
............................... 3180 min
-1
...............................3180 min
-1
tank capacity (Petrol) ...................................................... 12 l .............................................25 l .............................................25 l
Consumption at half load .........................................1,3 l/h ....................................... 2,3 l/h ........................................3,3 l/h
Oil amount .........................................................................0,6 l .............................................1,1l .............................................1,1l
Weight ...........................................................................41,5 kg ..................................... 65,7 kg ......................................84,6 kg
Dimensions L x B x H ...................... 570 x 435 x 525 mm ............670 x 515 x 510 mm ............720 x 530 x 655 mm
Degree of protection ...............................................IP 23 M ..................................... IP 23 M ..................................... IP 23 M
Noise and Vibration Information
Sound pressure level L
PA
........................................... 74,26 dB (A) ............................74,51 dB (A) ............................76,00 dB (A)
Uncertainty K = ...............................................................1,55 dB (A) .................................1,0 dB (A) ...............................0,40 dB (A)
Measured sound power level L
WA
1)
......................95,81 dB (A) ................................ 95,51
dB (A) ............................ 95,43 dB (A)
Guaranteed sound power level L
WA
1)
........................96 dB (A) ........................................96 dB (A) ........................................96 dB (A)
Wear ear protectors!
Measured according to
1)
2000/14/EG
Speci ed Conditions Of Use
This power unit has solely been designed for the
operation of electrical equipment with a maximum
power within the power unit performance data.
Higher starting current of induction appliances must
be considered.
The unit has been designed for operation of common
e ective and induction appliances such as light
chains, electric hand tools (drills, electric chain saws,
compressors).
When connected to a stationary device such
as heating, electrical power, air conditioning
equipment or for the supply of mobile homes, it
is necessary to contact a professional electrician
and heating manufacturer as far as connection
and grounding is concerned.
Not observing general regulations in force and
instructions from this manual does not make the
manufacturer liable for damages.
Protective equipment „Protective separation with
potential balancing“ is provided and integrated by
the producer.
30

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Gude GSE 6700 40635 wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info