rinsed with clean water when used in very dirty water. The
switching on and off heights can differ.
Thermal fuse/engine protection circuit-breaker
The drowned pump is equipped with an engine protection
circuit-breaker. If the engine is overheated, the engine
protection circuit-breaker will automatically switch the pump
off. Cooling time is app. 25 minutes, the pump subsequently
switches on. If the engine protection circuit-breaker switches
on, it is absolutely necessary to identify the cause and
remove it (see also the “Failure searching“). The given data
cannot be used for “family style“ repairs as it requires
specific professional knowledge. You must contact the
customer service department at any failures.
Instructions step by step
Connect the water hose to appropriate pump outlet (see
the Assembly and first putting into operation).
Fix the rope, chain, etc. to the pump handle and place it
to the right place.
Put the pump “sideways“ (pic. D) to the pumped
medium. Make sure the floating switch is in the operating
position.
Plug in the pump.
Rinse the pump with clean water after work finishing.
Operation
The pump is put into operation when the plug is inserted in
appropriate socket and the floating switch is in the required
position (see the Instructions). If the pump is lifted or
transported, it is done with an assembled handle and not with
the connecting cable. If the pump is being plunged, a rope,
chain, etc. fastened to the handle need to be used if
necessary.
At muddy, sandy or siliceous soil the pump must be hung on
a rope or chain or put on a suitable wide baseplate to be able
to work plunged. Sand and other abrasive solids reduce the
service life of hydraulic parts and seal of the pump and
therefore they need to be prevented. In frost conditions, the
pump must be removed from the pumped liquid. It is
necessary to absolutely make sure the pump is not exposed
to a risk of frost. The pump must be emptied and stored at a
place protected against frost.
Floating switch positions (pic. B + C)
The operating or shutdown point of the pump can be set
with various floating switch positions. In pic. B you can see
the float cable without any fixation change with full switch
radius. The figure 1 is the working position and figure 0 the
shutdown position.
Due to appropriate fixation of the float cable, possible on the
pump handle, the switch radius can be reduced when there is
no sufficient space or at a corresponding level control. The
figure 1 in pic. C is the working position and figure 0 the
shutdown position.
Continuous operation: The floater can be hung to the side
of the pump; in this position (the floater cable points
downward), the pump runs constantly.
Important: In case of continuous operation, under no
circumstances allow the operation of the pump without
fill!
Important: If the pump is to stay out of service for a longer period of time, make sure by all means necessary that both the
pipelines and the pump itself are emptied. Protect the device against frost. The pump can only be stored entirely empty.
Failures – causes - removal
Failures Causes Removal
Engine does not start
No system voltage
Blocked pump wheel
Floating switch in shutdown position
Check the voltage
Inspect the pump wheel for foreign objects
Check the water level (pic. B/C)
Pump does not suck
Pump without water
Water level too low
Blocked pump wheel
Let the air bubbles release (pic. D)
Switch the pump off, water level must go up.
Remove the obstruction
Insufficient amount of
water pumped
Dirty tube filter
Water level quickly going down
Maximum head of delivery exceeded
Transport guide broken
Clean the tube filter
Ensure sufficient inflow
Check the transport path length
Check the transport guide
Thermal detector
switching the pump off
Dirty tube filter
Water temperature too high
Pump running continuously at maximum pressure.
Clean the tube filter and let the pump cool down
Reduce the water temperature
Make more breaks
Inspections and maintenance
Be sent with the exception of cases described below, the pump for repairs required for service.
Safety instructions for inspections and maintenance
It is always necessary to interrupt feeding (plug pulled out of socket) and make sure the pump is not going to start before any pump
maintenance.
Only a regularly maintained and treated appliance can serve as a satisfactory aid. Insufficient maintenance and care can lead to
unforeseen accidents and injuries.
Inspection and maintenance plan
Time interval Description Any other details
As needed Cleaning and rinsing out Function check of the floating switch (C/D)
11

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Gude GSX 1100 wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info