Operator requirements
The operator must carefully read the Operating Instructions
before using the appliance.
Qualification
No special qualification is necessary for using the appliance
apart from detailed instruction by an expert.
Minimum age
The appliance can only be operated by persons over 18 years
of age. An exception includes youngsters operating the
appliance within their professional education to achieve
necessary skills under trainer's supervision.
Technical specifications
310/10/50 PRO
Connection: 230 V/50 Hz
Engine power: 2100 W/P1
Air jet capacity: 50 l
Suction power: 295 l per minute
Effective volume delivered: 210 l per minute
Cylinders: 1
Revolutions: 2800 revs per minute
Max. pressure: 10 bar
Weight: 35 kg
Article No. 75505
Transport and storing
The appliances are mobile and can practically be used
everywhere. If the compressor is wall-mounted, the minimum
distance of 30 cm must be kept to ensure appropriate cooling.
Appliances must necessarily be transported in a vertical
position; otherwise, oil will run out of the air hole of the engine
case. Prevent any hits to fittings.
Residual risks and protective measures
Electrical residual risks:
1. Direct electrical contact:
Risk of electric shock
To be used in electrical networks with a safety switch
against stray current (RCD-FI 30 mA) only.
2. Indirect electrical contact:
Risk of electric shock
To be used in electrical networks with a safety switch
against stray current (RCD-FI 30 mA) only.
Thermal residual risks:
1. Burns, chilblains:
Contact with the cylinder head and pressure lines
may cause burns.
Avoid both of these construction elements.
Exposure to noise:
1. Hearing damage:
Long stay in the immediate vicinity of the appliance
may damage hearing.
Wear headphones.
Neglecting the ergonomic principles:
1. Human behaviour / erroneous behaviour:
Compressed air current may lead to serious injuries.
Never hold the current in body holes.
Compressed air may cause tanks and tyres to break.
Do not exceed the max. filling size.
Installation and first start-up
Pic.2+3+4:
1. Remove the oil tank transport protection (if applicable)
pic. 3
2. Insert the attached oil gauge or plug instead.
3. Oil gauges or plugs, pic. 4 (failing to do so will increase
pressure in the engine case and oil will spirt).
Electrical connection; grounded connections to be used
only:
a) 230 V appliances are supplied with plugs fitted with a
ground contact
The following must be considered as far as 230 V
appliances are concerned:
If a too long extension cable with a too small cross-section
is used, voltage will drop, which may result in a more difficult
starting and increased engine load. If possible, we
recommend connecting the engine cable directly to the outlet
and using longer air hoses (another measure: see the winter
operation).
Recommended cable cross-section values for all 230 V
appliances:
Length within app. 10 m = 1.5
2
mm
Length within app. 20 m = 2.5
2
mm
Oil level check (for oil compressors only):
Oil may leak when the appliance is transported. Please check
the oil level on the aperture or using an oil gauge (more
information at a similar description with a picture)
Winter operation of compressors
The following must be considered in colder seasons
when operating the compressors: Oil gets thicken and its
viscosity increases with low temperatures in the engine case.
This makes first appliance starting before warm-up more
difficult. Proceed as follows when facing difficulties:
1. Reduce any pressure in the air jet to zero.
2. Open the drainage screw on the bottom part of the air
jet.
3. Unless being absolutely necessary, do not use any
extension cable!
4. Switch on the compressor and let it run (without any
extension cable). With the drainage screw open, let it run
for app. 2-3 minutes to enable air to leak and thus
pressure to reduce. The appliance will warm in these 2-3
minutes to enable further operation.
5. After 2-3 minutes, close the drainage screw. The air jet
can now be filled and pressure increased.
6. Change oil – use 5W40 synthetic oil for light running
or, as alternative, SAE 80 gearbox oil.
7. If the compressor does not start despite all the effort, put
it out of operation for half an hour to one hour in a
tempered room to warm up.
8. Please contact the customer service centre for more
difficulties.
All documents necessary for proper operation are
included in the supply (see the simple regulation for
pressure vessels). When used for industrial purposes,
an inspection is necessary before the appliance is used
for the first time under the operating safety regulation.
Safety instructions for first start-up
Procedure
1. Switching compressors on and off:
The On/Off button (rotary and pull switch) is up on the
pressure switch cover at all compressors. Switch
positions are marked as "0" and "I". When plugging, the
switch must be in the "0" position, then the appliance
15
15

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Gude Pro 310-10-50 PRO 75505 wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info