665727
10
Zoom out
Zoom in
Vorherige Seite
1/33
Nächste Seite
10
RECOMMENDATION TO REDUCE ELECTRO-MAGNETIC EMISSIONS
General
The user is responsible for installing and using the welding equipment according to manufacturer’s instructions. If
electromagnetic disturbances are detected, then it shall be the responsibility of the user of the welding equipment to
sort the situation out with the technical assistance of the manufacturer.
Evaluation of the welding area
Before installing the unit, the user shall make an assessment of potential electromagnetic problems in the
surrounding area
a. Other wiring, control cables, telephones and communication cables; above, below and adjacent to the
welding machine
b. Radio and television transmitters and receivers;
c. Computer and other control equipment;
d. Equipment critical for safety purposes such as safety checks of industrial equipment;
e. The health of persons in the vincity, for example persons who wear pacemakers and hearing aids;
f. Equipment used for calibration or measurements;
g. The immunity of other equipment in which the equipment is to be used. The user must ensure that other
equipment used in the same placet is compatible. This may require additional protection measures;
h. The time of day when welding or other activities are carried out
i. The size of the area to be considered will depend on the structure of the building and any other
processes in the area. The surrounding area may extend beyond the boundaries of the buildings.
Recommendation to reduce electro-magnetic emission
a. Mains power supply: the equipment must be connected to the power mains as specified in the
Manufacturer’s instructions. If interference occurs, additional precautions such as filtering of the mains
supply may be required. The supply cable in the welding machine’s permanent installations may have to
be screened in metal conduits or similar.The screening should be electrically continous for the entire
lengh of the cable. It should also beconnect to the welding machine with a good electrical contact
between the metal conduit and the casing.
b. Welding cables: The welding cables should be kept as short as possible and should be positioned close
together, running at or close to the floor level.
c. Protection and reinforcement: Selective screening and shielding of other cables and equipment in the
surrounding area may alleviate problems of interference. Screening of the entire welding area may be
considered for special applications
d. Connect the earth directly to the metal piece to be welded: Where necessary, the connection of
the workpiece to earth should be made by a direct connection to the workpiece, but in some countries
where direct connection is not permitted, the bonding should be achieved by suitable capacitance,
selected according to national regulations.
TROUBLESHOOTING
Anomalies
Causes
Remedies
MMA-TIG
The device does not deliver any current and the
yellow thermal indicator lights up.
Thermal protection is active
Wait for the end of the cooling period, around 2
minutes. The indicator light turns off.
The display is on but the device does not deliver
any current.
The earth clamp or electrode holder is
not properly connected to the unit.
Check the connections.
The unit is on and you feel tingling sensation while
touching the unit’s case.
The welding unit is not correctly
connected to the earth.
Check the plug and the earth of your electrical
network.
The display is on but the device does not deliver
any current.
The earth clamp or electrode holder is
not properly connected to the unit.
Check the connections.
When starting up, the display indicates .
The voltage is not within the range 230V
+/- 15%
Have the electrical installation checked.
TIG
Unstable arc
Failure of the tungsten electrode
Ensure the correct size of electrode is being used
Ensure the tungsten electrode is correctly prepared
Gas flow rate set too high Reduce gas flow rate
The tungsten electrode gets oxidised and tern at
the end of welding.
Welding zone
Protect welding zone against air flow
Default coming from post-gas or the gas
has been stopped prematurely.
Check and tighten all gas connections. Wait until
the electrode cools down before stopping the gas.
The electrode melts
Polarity error
Check that the earth clamp is connected to the +
pole
10

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Gys PROGYS 200A PFC wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info