564849
6
Zoom out
Zoom in
Vorherige Seite
1/10
Nächste Seite
5.4. Glass cleanness
The cleanness of the transparent glass depends on the type of the fuel, proper combustion air
supply (this is applied especially to the secondary air) , the chimney effect and last but not
least on the way how the fireplace insert is operated. It is recommended to load one layer of the
wood only: the logs should be laid evenly, farther from the glass (as far as possible). The rule is the
same for coal cakes as well (keep the distance 5 to 0 mm between them). If the glass is dirty, we
recommend to increase the firing intensity by opening the primary air regulator, which usually
supports the self-acting cleaning process.
5.5. Operation during temporary period and at worsened weather conditions
For temporary periods , for example, during the time when outdoor temperature is above 15
o
C,
during rainy and wet days, in case of gusty wind, etc. the chimney effect may worsen thus the smoke
is not led away in full as usual. Therefore, during such period, you should operate the fireplace
insert with smallest possible quantity of fuel, to allow improving the firing process and the chimney
effect by opening the air inlets in case you need to make adjustments.
5.6.
Fireplace insert function adjustment
Some models are provided with the so-called blind element that serves as the chimney effect
conditioner as well. After removal of such blind element, those models must be completed with
warm-water exchanger allowing connection to heating bodies to provide heat in adjacent rooms or
with a water back boiler. A warm water exchanger may be supplied as special accessory (detailed
instructions for operation and installation provided). Order the installation of fireplace insert with
warm water exchanger at specialist company (ask for installation following from the project
documentation).
Caution! A fireplace insert equipped with a warm water exchanger must not be operated
without the connection to the warm water distribution system or the water filled, or without
anti-freezing mixture, respectively.
For any installation of warm water pipeline, the requirements on heat systems and
networks in buildings valid in the country of installation must be adhered to.
Related regulations:
Heat systems in buildings – Safety devices
Heat systems in buildings – Design and installation
Heat systems in buildings – Hot water production
Heat systems in buildings – Designing hot water heat systems
Heaters using fossil fuel designed for dwelling space
Built-in heat devices and stove inserts using solid fuel
Caution! If you install a fireplace insert with a warm water exchanger, before lining and
before first fire, you must connect the exchanger in the heating system operated in order to
check the warm water distribution system for leak.
5.7. Ash removal
Depending on the length and the intensity of the firing process, you need to use a fire hook or poking
lever (if installed with the particular model) in order to knock the ash down the grate to the ashpan.
Monitor the content of the ashpan - do not allow too much ash in it. Excessive ash may block
the air supply under the grate thus causing problems at fire setting or burning.
Always empty the ashpan when cold. The best approach is to empty the ashpan just before you start
preparing the next fire. With some models, the ashpan is located just under the grate
(impossible to take it away on the side). If this is the case, empty the ashpan only if cold,
while the heating system is not in operation. Ash from wood may be used for composting or for
fertilizing.
Caution! Before you touch the ashpan to empty it, check it for fire brand. Prevent any likely
fire in the dustbin.
6. CLEANING AND MAINTENANCE
6.1. Cleaning
The fireplace insert (cold) needs cleaning at least once a year (after the season), or twice or more (
if needed). During the cleaning ,you should remove any dirt caught in the smoke flue, the firing area
and on the partitions. Loose parts of the fireclay lining should be repaired (i.e. replaced). Check the
fireclay lining for integrity even during the heating season. The gaps between the brick shapes are
designed for heat dilatation, to avoid brick cracking. Therefore YOU SHOULD NOT fill any sealing in
the gaps (as it used be before with older heating devices).
Cracked fireclay bricks do not lose the function unless they are completely fallen out of the
position!
In the course of the cleaning procedure, we recommend you to remove all movable partitions (for
easier access in the area above them). To clean the glass, apply standard cleaning agents designed
for cleaning stove, cooker or oven. Use a soft cloth or paper, or special agents designed for cleaning
fireplace glass.Only clean the glass when cold. For cleaning the painted surface, never use water: it
is recommended to clean such surface with sponge or soft flannel cloth.
Caution! With selected types of fireplace insert, the vertical side of the firing area is provided with
VERMICULITE. The same material is used for some chimney effect conditioners. The material is
irreparable. In case of any damage, just have it replaced. Vermiculate products are characteristic
with top heat-insulating parameters and good resistance to cracking. The resistance to abrasion is
somehow lower so it is recommended to keep this in mind while reloading and cleaning.
6.2. Sealing lines and tapes
Contact areas of doors and glass (or other parts of the heating device) are provided with a special
glass-ceramic sealing line (tape) that is resistant to high temperatures. We recommend you to check
the tape for integrity, and have it replaced if necessary.
After some time, any newly installed sealing tape lays flat so it is recommended to check the
tightness (the glass tightly installed in the door construction) after approx. 3 months of usage. If you
find any release, tighten the glass holders (carefully!)
6.3. Spare parts
In case of repair, use only original spare parts recommended by the manufacturer, see Chapter
10.3 (Recommended spare parts). Identify the spare part with use of the Technical Card (a part of
the supply).
11 12
6

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Haas-Sohn ASCIM-II wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Andere Handbücher von Haas-Sohn ASCIM-II

Haas-Sohn ASCIM-II Installationsanweisung - Deutsch - 8 seiten


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info