4: Finally, plug the transformer cable into the switch plug in
the transformer plug
The indication light should light up. Congratulations!
From now on, you are breathing cleaner air.
5: To switch the IonFlow 50F & 50F Style on and off:
Air purier ON (upper indication light on) & decorative light
OFF
Air purier ON (upper indication light on) & decorative light
ON
Air purier OFF (upper indication light off) & decorative
light OFF
6: The decorative lights can be changed easily.
4B. Assembly and installation of 50C
S E E P I C T U R E S O N PA G E 3 3
Assemble the air purier in the following order:
For ceiling installation: Drill an 8mm hole in the ceiling to
attach the wall plug and ceiling hook. Insert the plug into the
hole and screw in the ceiling hook.
For suspended ceilings: Consult an electrician for the most
appropriate solution
NB. Ensure that the distance from the wall to the air purier
is at least 3 feet / 1 metre
A-D: Thread the cable through the loops of the pressure
relief device.
E-F: Attach the pressure relief device to the top of the ion
generator (at the outlet on the plastic tube) and ensure that it
snaps into the holes
G: Connect the plug to socket on the ion generator
H: Attach the cable to the pressure relief hook. The air puri-
er should hang down at least 2 feet / 60 cm from the ceiling
I: Hang the pressure relief hook from the ceiling hook
J-K: Hold the metal hook on the ion generator. Then care-
fully lift the collector (aluminium cylinder) from underneath
(where the corona needles are) up and over the metal hook
L: Then let the collector slide back down and rest on the
metal hook. NB. This connection is vital in order for the air
purier to function.
• Finally, plug in the transformer plug at the wall socket. If
an extension lead is required, attach this to the transformer
cable.
The indication light should light up. Congratulations!
From now on, you are breathing cleaner air.
5. Cleaning and maintenance
Always unplug the transformer plug before cleaning the air
purier.
• Do NOT wash the collector in the dishwasher.
• Do not use cleaning products that contain alcohol solutions,
ammonia or alkaline substances, as these products may
damage the air purier.
• The collector should be cleaned around once a week or as
and when required. The collector may require more frequent
cleaning if used in highly contaminated environments.
Cleaning the collector:
IonFlow 50F & 50F Style: Remove the collector by lifting up
the ion generator with the collector attached. Then hold in
the metal hook and pull the collector downwards (pictures
1-3 on page 32, in reverse). NB. The ion generator may be
damaged if you pull it upwards!
IonFlow 50C: Hold in the metal hook on the ion generator
and move the collector down (pictures J-L on page 33, in
reverse)
1. Clean the collector with washing-up liquid, warm water
and a soft sponge/dish brush
2. Dry the collector with a dishtowel
3. Put the collector back on the ion generator according to
the earlier instructions.
If you have followed all the above instructions but the col-
lector is not clean, try the following:
1. Spray cleaning uid onto the collector and let it work for
5 minutes
2. Using a damp sponge, rub any remaining spots until they
disappear
3. Wipe the collector using a clean, damp sponge
4. Dry the collector with a towel and place it back on the ion
generator according to the earlier instructions.
5. Repeat the above procedure if necessary
Cleaning the ion generator, corona needles and acrylic
stand:
• Once every four months you may need to carefully clean
the fragile corona needles. Use a small brush (e.g. a
toothbrush) and carefully brush away the thin layer of white
lime scale and dirt which may have become attached to the
needles. Do not use pressure or water when you clean the
needles.
• Clean the ion generator and the acrylic stand with cleaning
spray and a damp cloth or sponge. Wipe clean and rub away
any remaining dirt. Dry with a towel. Do not allow the top and
bottom to come into contact with water and be careful with
the corona needles on the ion generator.
ENGLISH
5

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Habitat IONFLOW 50 wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info