Page 9 of 16 AquaRite® Pro LS Rev. D
Settings Menu
The Settings Menu is used to configure the AquaRite Pro LS and adjust various settings. Access this menu by pushing
the Settings Menu button. Refer to the information below when setting system operating parameters.
To access the Settings Menu
Setting
Menu - Locked Press BOTH buttons SIMULTANEOUSLY for 5 seconds to unlock
Setting
Menu - Unlocked Move to settings menus
NOTE: To prevent unauthorized access, the settings menu automatically “locks” after 2 minutes of no
buttons being pressed.
Rotates between available languages
Move to previous/next settings menu
Language
English
Language
The AquaRite Pro LS can display the following languages: English (default), French, Spanish, Italian,
German, Portuguese and Dutch. Select the desired language.
Toggle between Pool and Spa
Move to next menu item
Body of Water Type
Pools
Toggle between Salt (default) and Minerals
Move to next menu item
Display
Salt
Toggle between available cell types
Move to previous/next menu item
Cell Type
T-CELL-15
Push to access Chlorinator option
Move to previous/next menu item
Chlor. Config.
+ to view/change
Body of Water Type
Select Pool or Spa. "Pool" should be selected for bodies of water over 4 M³. The AquaRite Pro LS will
adjust its operation according to this selection.
Display
Allows for the display of salt (default) or mineral values.
Cell Type Selection
Ref. AquaRite Pro LS T-Cell provided Cell Type Selection in the menu
AQR-PRO-75LSE T-CELL-LS15-E T-CELL-15
AQR-PRO-50LSE T-CELL-LS9-E T-CELL-9
Note that the unit will not function properly if the wrong cell is selected.
Sensing System
Enabled
Toggle between Enabled and Disabled (default)
Move to next menu item
If AQL-CHEM is used
Chemistry Config.
Wizard + to enter
Push to access Chemistry Cong. Wizard
Move to previous/next menu item
Requires use of the AQL-CHEM Sensing Kit. Following the steps of the Chemistry Config. Wizard will
set up the AQL-CHEM to sense ORP and pH levels. The AquaRite Pro LS will generate the correct
amount of chlorine to properly sanitize the pool based on the AQL-CHEM sensing function. Refer to the
AQL-CHEM manual for more detailed information.
If ORP Auto Sensing is not used
Chlorinator
50%
Adjust the desired output % for the pool
Move to previous/next menu item
The desired output % is used to control the amount of chlorine the AquaRite Pro LS generates. Raise
this setting to increase chlorine level and lower it to decrease chlorine level. If an AQL-CHEM is being
used and ORP Auto Sensing is enabled (see AQL-CHEM manual), the AquaRite Pro LS will override the
desired chlorinator output % setting and generate chlorine based on the pool's ORP level.
26

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Hayward Aqua Rite Pro LS wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info