USE ONLY HAYWARD GENUINE REPLACEMENT PARTS
5 Pump
GENERAL POINTS
Install the pump at a suitable distance from the pool to reduce the distance between the suction point and the
pump as much as possible to avoid pointless excessive pressure drops on the hydraulic circuit. However, it
is essential to comply with the safety distance required by the current installation standard (3.5 metres mini-
mum). Install and use the product at an altitude less than 2000m.
Install the pump in a dry, well-ventilated place. The motor requires the air to circulate freely around it to allow na-
tural ventilation. Check regularly that no objects, leaves or other debris are blocking the motor cooling system.
The pump must be installed to ensure that the external disconnection switch incorporated into
the xed unit is visible and easily accessible. The switch must be located near to the pump.
The pump must be permanently installed on a concrete base using 8mm lag screws suitable for 3 concrete,
screwed into drilled implantation holes. Lock washers must be used to prevent the installation lag screws
working loose over time.
If the pump has to be mounted on a wooden board, Ø 8mm hexagonal wood screws
must be used combined with lock washers to prevent the screws working loose over time.
The acoustic pressure of HAYWARD pumps is less than 70 dBA.
Necessary measures:
• Connect the pump to the earth: Never operate the pump unless it is connected to the earth.
• Connect the pump with a H07RN-F 3G1,5mm² type cable.
• Include a 30mA di󰀨erential protection to protect people against electric shocks which may be caused by a
breach of the equipment’s electrical insulation.
• Include short-circuit protection (the rating is determined according to the value given on the nameplate on
the motor).
• Include a means of disconnection from the power supply having an opening distance on the contacts of all
the poles ensuring the power supply is completely cut o󰀨 under the conditions of a category III overvoltage.
Three phase electric motor:
Check the running direction of the pump motor (a label is provided on the motor housing to indicate the motor
running direction).
If so required by regulations and whatever the motor type, in addition to the devices mentioned above, it is
also necessary to install a thermal-magnetic motor circuit breaker GV2ME or similar one with the same tech
specs, in accordance with the indications on the motor name-plate.
The table on page 48 indicates the various characteristics of the motors tted to our pumps.
3.5 m
ZONE 0
ZONE 2
ZONE 2
ZONE 0
1,50 m
2,50 m
2,50 m
1,50 m2,00 m2,00 m 1,50 m
ZONE 1
1,50 m
OK OK
5

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Hayward K-Flo Pump wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info