Before first switch-on
For safety reasons, it is recommended that the wa-
ter installation of the device is vented before the
first switch-on. In order to do so, water inlet to the
softener must be shut off. Consecutively, the sam-
pler valve after the water softener must be opened,
whereas the mains valve of the building shall be
opened gently. Water flowing will push air out
through the open sampler valve. A bubbling sound
will appear and water may gush. One shall wait un-
til the flow of water stabilizes and then close the
sampler valve. The system is now vented.
Venting. Filling water into the device
In order to vent the device, the sampler valve after
the water softener must be opened, whereas the
mains valve of the building shall be opened gently.
Then, one shall proceed as in the case of venting
the entire system. It is recommended that the de-
vice is filled with water gradually, with breaks, in
order not to increase pressure inside the device
abruptly.
ATTENTION! The salt tank must be filled with salt and water before the first switch-on of
the device. One shall wait 30 minutes before salt dissolves in water. Resin regeneration
must then be performed.
First resin regeneration (ONLY 230459 model)
Regeneration must be activated with the usage of the manual regeneration button. Regeneration will
be done automatically. After it finishes, the device is ready to operate.
Operating cycles of the device
In serve the device is in the position of the first operation cycle, i.e. water treatment. Water
flows though the device. Raw water enters the container with resin through the
controller, flows through the resin and is directed upwards, through a distribution
pipe, to the controller and further to the system.
BACKWASH
The device is in the position of the second operation cycle - anti-current rinse
(backwash). Raw water enters the container with the filter bed through an inlet valve and
is directed downwards with a central pipe. Water flows through the resin, rinses it and
fluffs it, and then is directed to sewage. In this cycle the controller shuts off water inlet
to the water system. Thanks to which the controller protects the water system against
the penetration of impurities from rinsing.
BRINE DRAW SLOW RINSE T
he device in the position of third operation cycle - regeneration with brine and slow
rinsing. Raw water with brine enters to the container with the filter bed through an inlet
valve. Flowing through the bed in the tank, it regenerates its ion exchange capacity. After
flowing through the bed, water is directed to sewage. After all brine in the brine tank is
used up, the ion exchange bed is rinsed slowly with water, which guarantees thorough
rinsing brine and proper regeneration conditions. In this cycle the controller shuts off
water inlet to the water system. Thanks to which the controller protects the water
system against the penetration of impurities from rinsing.
7

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Hendi 230442 wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info