Your new digital blood pressure monitor uses the oscillometric method
of blood pressure measurement. This means the monitor detects your
blood ‘ s movement through your brachia! artery and converts the
movements into a digital reading. An oscillometric monitor does not
need a stethoscope, so the monitor is simple to use. This automatic
blood pressure monitor could measure the systolic pressure, diastolic
pressure and pulse, the components are included the body, cuff and
printed instruction manual.
Intended Use:
Arm Type Automatic Blood Pressure Monitor is a digital monitor
intended for use in measuring blood pressure and pulse rate in adult
patient population via non-invasive oscillometric technique in which
an inatable cuff is wrapped around the arm. It can be used at medical
facilities or at home. Intelligent ination will reduce the uncomfortable
feeling by incorrect ination, and shorten the measurement time,
prolong the cuff’s usage lifetime.
1 *199 sets memory function, each measurement result will be
displayed on the screen, and automatically stored. This unit has blood
classication index, could easy to check your blood pressure. Please
read the manual carefully before you use the unit, and keep the manual
well after using.
SAFETY INFORMATION
To assure correct use of the product, basic safety measures should
always be followed including the warning and the caution listed in the
instruction manual:
The following symbols may appear in this manual, on the label, on the
device, or on it’s accessories. Some of the symbols represent
standards and compliances associated with the device and its use.
WARNING: This alert identies hazards that may cause
serious personal injury or death.
CAUTION: This alert identies hazards that may cause minor
personal injury, product damage, or property damage.
Type BF applied part
Species serial number
CE Mark: conforms to essential requirements of the Medical
Device Directive 93/42/EEC.
DISPOSAL: Do not dispose this product as unsorted munic-
ipal waste. Collection of such waste separately for special
treatment id necessary.
Direct current
Operating instructions Follow instructions for use
CAUTION: Consult accompanying documents
Those who have arrhythmia, diabetes, blood circulation or apoplexy
problem, please use under the physician’s instruction.
Contact your physician for specic information about your
blood pressure. Self diagnosis and treatment which use mea-
sured results may be dangerous. Follow the instructions of
your physician or licensed healthcare provider.
Please place on a high place where children can’t touched.
No modication of this equipment is allowed.
Do not modify this equipment without authorization of the
manufacturer.
If this equipment is modied, appropriate inspection and
testing must be conducted to ensure continued safe use of
equipment.
The cuff hose around neck may cause the suffocation.
The swallowing of small part like packaging bag, battery,
battery cover and so on may cause the suffocation.
Please don’t use a dilution agent, alcohol or petrol to clean
the unit.
Please don’t hit heavily or fall down the product from a high
place. Use the right cuff, otherwise it can not work.
Never leave any low battery in the battery compartment since
they may leak and cause damage to the unit.
Please take off the battery if you won’t use in 3 months.
Replace the new batteries if the unit display a low battery
symbol.
Do not mix the old and new batteries.
Do not use a cellular phone near unit. It may result in opera-
tional failure.
Please avoid using in high radiant area in order to make your
measuring data correctly.
Do not use the equipment where ammable gas (such as
anesthetic gas, oxygen or hydrogen) or ammable liquid(such
as alcohol) are present.
WARNING:
Do not dispose of electrical appliances as unsorted municipal waste,
use separate collection facilities. Contact you local government for
information regarding the collection systems available. If electrical
appliances are disposed of in landlls or dumps, hazardous substances
can leak into the groundwater and get into the food chain, damaging
your health and well-being.
The user must check that the equipment functions safely and see
that it is in proper working condition bfore being used.
PRODUCT STRUCTURE
body
AC/DC Socket
LCD Display
Start / Stop
Memory button
display
Cuff size and connection
The accessories cuff is M size, for upper-arm circumference 22-32cm
use. The cuff is treated as the applied part. Insert the connector with
cuff tube into the hole which is on the left side of the device as picture.
(Only provided cuff can be used, can not change to any other branded
cuff.)
Battery installation
Remove the battery cover from the battery compartment, Insert the
battery,
a) Remove the battery cover as picture showed.
Home medical tools
HHA282104
User manual
AUTOMATIC BLOOD PRESSURE MONITOR
Systolic blood pressure
Unit
Diastolic blood pressure
Pulse rate
Alarm clock
Irregular heart beat
Low battery symbol
Time
Memory symbol
Year / Month / Date
5

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Hyundai HHA282104 wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info