97
9
TONE SQUELCH OPERATION (Multi-function receiver/Component screens only)
9
■ Tone scan operation
By monitoring a signal using with pocket beep, tone or DTCS
squelch, you can determine the tone frequency or DTCS
code necessary to open the squelch.
qClick zFMx to select FM mode.
wSelect the tone type, tone squelch or DTCS to be scanned,
then set the desired tone squelch frequency or DTCS
code. (pgs. 94, 95)
eClick zT-SCANx to start the tone scan.
• “AUTO Scan” blinks and zAUTOx appears while scanning.
rWhen the TSQL tone frequency or 3-digit DTCS code is
matched, the squelch opens and the tone frequency is
temporarily programmed into the selected memory chan-
nel.
• The tone scan pauses when a TSQL tone frequency or 3-digit
DTCS code is detected.
• The decoded TSQL tone frequency or 3-digit DTCS code is used
for the tone encoder or tone encoder/decoder depending on the
selected tone condition or type in step w.
tTo stop the scan, click zSTOPx or zT-SCANx.
☞ NOTE: The decoded tone frequency is programmed tem-
porarily when a memory or call channel is selected. How-
ever, this will be cleared when the memory/call channel is
re-selected.