101
SAVE THESE INSTRUCTIONS
Page 25
(101) MODEL 8110 KRYSTAL CLEAR™ DELUXE SALTWATER SYSTEM (SALT IN POOL) ENGLISH 7.5” X 10.3” PANTONE 295U 08/07/2008
English
INSUFFICIENT
CHLORINE
WHITE FLAKES IN
THE WATER
NO LED DISPLAY
• Insufficient operating hours of
the Saltwater System.
• Insufficient (Less than
2000ppm) salt level in pool
water.
• Chlorine loss due to intense
sunlight exposure.
• The bather load has increased.
• Clogged or dirty electrolytic cell.
• Excessive calcium hardness is
present in pool water.
• No power supply.
• Power fuse blown.
• LED failure.
• Increase the Saltwater System
operating time per day. See “Operating
Instructions”.
• Test the Salt Level with Test Kit, and
adjust as needed. See “Salt & Pool
Water Volumes”.
• Use Pool Cover when the pool is not
use and/or when the unit is operating.
• Increase the Saltwater System
operating time per day. See “Operating
Instructions”.
• Remove the cell for inspection, clean it
if necessary. See “Maintenance”.
• Drain about 20 to 25% of the pool
water and add fresh water to decrease
the calcium hardness. Visually inspect
the electrolytic cell for scale build-up
and clean the electrolytic cell if
necessary.
• Check for power cord loose or not
connected properly.
• Contact Intex Service Center for
replacement.
• Contact Intex Service Center for
replacement.
TTRROOUUBBLLEESSHHOOOOTTIINNGG GGUUIIDDEE
TROUBLESHOOTING GUIDE
PROBLEM CAUSE REMEDY
IMPORTANT
If you continue to experience difficulty, please contact our Consumer
Service Department for assistance. See back cover for contact
information.