771590
13
Zoom out
Zoom in
Vorherige Seite
1/156
Nächste Seite
Page 12
Refer to the following diagram to ensure proper distance from walls and ceiling:
Step 2: Attach mounting plate to wall
The mounting plate is the device on which you
will mount the indoor unit.
1.
Remove the screw that attaches the mounting
plate to the back of the indoor unit.
2.
Place the mounting plate against the wall
in a location that meets the standards in
the Select Installation Location step. (See
Mounting Plate Dimensions for detailed
information on mounting plate sizes.)
3.
Drill holes for mounting screws in places that:
have studs and can support the weight of
the unit
correspond to screw holes in the mounting
plate
4.
Secure the mounting plate to the wall with
the screws provided.
5.
Make sure that mounting plate is flat against
the wall.
NOTE FOR CONCRETE OR BRICK WALLS:
If the wall is made of brick, concrete, or similar
material, drill 5mm-diameter (0.2in-diameter)
holes in the wall and insert the sleeve anchors
provided. Then secure the mounting plate to
the wall by tightening the screws directly into
the clip anchors.
Step 3: Drill wall hole for connective piping
You must drill a hole in the wall for refrigerant
piping, the drainage pipe, and the signal cable
that will connect the indoor and outdoor units.
Fig. 3.1-b
12cm (4.75in)
or more
2.3m (90.55in) or more
12cm (4.75in)
or more
15cm (5.9in) or more
1.
Determine the location of the wall hole based
on the position of the mounting plate. Refer
to Mounting Plate Dimensions on the
next page to help you determine the optimal
position. The wall hole should have a 65mm
(2.5in) diameter at least, and at a slightly
lower angle to facilitate drainage.
CAUTION
When drilling the wall hole, make sure to
avoid wires, plumbing, and other sensitive
components.
2.
Using a 65mm (2.5in) or 90mm(3.54in)
(depending on models )core drill, drill a
hole in the wall. Make sure that the hole
is drilled at
a slight downward angle, so
that the outdoor end of the hole is lower
than the indoor end by about 5mm to 7mm
(0.2-0.275in). This will ensure proper water
drainage. (See Fig. 3.2)
3.
Place the protective wall cuff in the hole. This
protects the edges of the hole and will help
seal it when you finish the installation process.
Page 13
Wall
Indoor Outdoor
mm7-5
(0.2-0.275in)
Fig.3.2
MOUNTING PLATE DIMENSIONS
Different models have different mounting plates.
In order to ensure that you have ample room to
mount the indoor unit, the diagrams to the right
show different types of mounting plates along
with the following dimensions:
Width of mounting plate
Height of mounting plate
Width of indoor unit relative to plate
Height of indoor unit relative to plate
Recommended position of wall hole (both
to the left and right of mounting plate)
Relative distances between screw holes
Fig. 3.2
Model B
Model D
302mm(11.9in)
805mm(31.7in)
1106mm(43.5in)
599mm(23.6in)
342mm(13.5in)
Model C
964mm(37.9in)
482mm(19in)
325mm(12.8in)
406.4mm(16in)
452.7mm(17.8in)
249mm(9.8in)
153mm(6in)102mm(4in)
39mm(1.5in)
pipe hole
φ65mm
2.56 in
pipe hole
φ65mm
2.56 in
pipe hole
φ65mm
2.56 in
pipe hole
φ65mm
2.56 in
pipe hole
φ65mm
2.56 in
pipe hole
φ65mm
2.56 in
Indoor unit outline
54mm(2.1in)
Model A
717mm(28.2in)
302mm(11.9in)
318mm(12.5in)
409mm(16.1in)
249mm(9.8in)
153mm(6in)102mm(4in)
39mm(1.5in)
pipe hole
φ65mm
2.56 in
pipe hole
φ65mm
2.56 in
Indoor unit outline
54mm(2.1in)
71mm(2.80in)
132mm
(5.20in)
219mm(8.62in)
262mm(10.31in)439mm(17.28in)
Indoor unit outline
Indoor unit outline
174mm
(6.85in)
320mm(12.60in)
130mm
(5.12in)
55mm(2.17in)
558mm(21.97in)
Correct orientation of Mounting Plate
Φ
NOTE: When the gas side connective pipe is
16mm(5/8in) or more, the wall hole should
be 90mm(3.54in).
13

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Inventor P9VO32 Passion Eco wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Andere Handbücher von Inventor P9VO32 Passion Eco

Inventor P9VO32 Passion Eco Zusatzinformation - Deutsch - 60 seiten

Inventor P9VO32 Passion Eco Bedienungsanleitung - Deutsch - 76 seiten

Inventor P9VO32 Passion Eco Zusatzinformation - Englisch - 24 seiten

Inventor P9VO32 Passion Eco Zusatzinformation - Englisch - 60 seiten

Inventor P9VO32 Passion Eco Bedienungsanleitung - Englisch - 76 seiten


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info