771744
27
Zoom out
Zoom in
Vorherige Seite
1/136
Nächste Seite
Page 26
Outdoor Unit Installation
Outdoor Unit Installation Instructions
Step 1: Select installation location.
The outdoor unit should be installed in the
location that meets the following requirements:
o Place the outdoor unit as close to the indoor
unit as possible.
o Ensure that there is enough room for
installation and maintenance.
o The air inlet and outlet must not be
obstructed or exposed to strong wind.
o Ensure the location of the unit will not be
subject to snowdrifts, accumulation of leaves
or other seasonal debris. If possible, provide
an awning for the unit. Ensure the awning
does not obstruct airow.
o The installation area must be dry and well
ventilated.
o There must be enough room to install the
connecting pipes and cables and to access
them for maintenance.
o The area must be free of combustible gases
and chemicals.
o The pipe length between the outdoor and
indoor unit may not exceed the maximum
allowable pipe length.
o If possible, DO NOT install the unit where it
is exposed to direct sunlight.
o If possible, make sure the unit is located far
away from your neighbors’ property so that
the noise from the unit will not disturb them.
o If the location is exposed to strong winds (for
example: near a seaside), the unit must be
placed against the wall to shelter it from the
wind. If necessary, use an awning.
(See Fig. 9.1 & 9.2)
o Install the indoor and outdoor units, cables
and wires at least 1 meter from televisions or
radios to prevent static or image distortion.
Depending on the radio waves, a 1 meter
distance may not be enough to eliminate all
interference.
Strong wind
Strong wind
Strong wind
Fig. 9.1
Fig. 9.2
Step 2: Install outdoor unit.
Fix the outdoor unit with anchor bolts (M10)
>60cm / 23.6”
Fix with bolts
Be sure to remove any obstacles
that may block air circulation.
Make sure you refer to Length
Specications to ensure there is
enough room for installation and
maintenance.
Fig. 9.3
9
CAUTION
Page 27
NOTE:
The minimum distance between the
outdoor unit and walls described in the
installation guide does not apply to airtight
rooms. Be sure to keep the unit unobstructed
in at least two of the three directions (M, N, P)
(See Fig. 9.5)
Fig. 9.5
Outdoor Unit Mounting Dimensions
Rows of series installation
L H L 1/2H
L A
25 cm / 9.8” or more
1/2H < L H
30 cm / 11.8” or more
L > H Can not be installed
The relations between H, A and L
are as follows.
B
A
D
The mounting dimensions vary among different outdoor units.
The fixing bolt head diameter should be more than 12mm.
Outdoor Unit Dimentsion (mm) Mounting Dimentsion (mm)
W H DAB
952 1333 415 634 404
900 1170 350 590 378
Fig. 9.3
M
N
P
30 cm / 12” from back wall
60 cm / 24” above
30 cm / 12” on left
30 cm / 12”on right
200 cm / 79” in front
W
H
Outdoor Unit Dimentsion (mm) Mounting Dimentsion (mm)
W H DAB
681 434 285 460 292
700 550 275 450 260
300
333
363
420
555
554
702
810
770
800
845
946
487
514
540
673
298
340
350
403
Fig. 9.4
W
H
A
B
D
27

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Inventor V5MFI32-60 wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Andere Handbücher von Inventor V5MFI32-60

Inventor V5MFI32-60 Zusatzinformation - Englisch - 44 seiten


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info