98 99
9796
8e) ALARM FEATURE
*Weekday Alarm
The alarm sound will be activated and the icon will be
flashed on weekday when it is armed and the alarm time
is reach.
*Single Alarm
The alarm sound will be activated and the icon will be
flashed once when it is armed and the alarm time is
reach. Once it finished, it will be disabled automatically.
*Pre-Alarm
The pre-alarm sound will be activated and the icon
will be flashed if outdoor temperature under or equal
two degree C. Which is programmable 15, 30, 45, 60 or
90 minutes earlier than the weekday alarm or single
alarm time.
PRECAUTIONS
This product is engineered to give you years of
satisfactory service if you handle it carefully. Here are
a few precautions:
1. Do not immerse the unit in water.
2. Do not clean the unit with abrasive or corrosive
materials. They may scratch the plastic parts and
corrode the electronic circuit.
3. Do not subject the unit to excessive force, shock, dust,
temperature or humidity, which may result in
malfunction, shorter electronic life span, damaged
battery and distorted parts.
4. Do not tamper with the unit's internal components.
Doing so will invalidate the warranty on the unit and
may causeunnecessary damage. The unit contains no
user-serviceable parts.
5. Only use fresh batteries as specified in the user's
manual. Do not mix new and old batteries as the old
ones may leak.
6. Always read the user's manual thoroughly before
operating the unit.
9. SPECIFICATIONS
Temperature Measurement
Main unit
Indoor Temperature measurement
Proposed operating range  : 0°C to +50.0°C
32.0°F to 122.0°F
Humidity Measuring range :R.H. 10% to 95%
at 25˚C ( 77˚F )
Temperature resolution  : 0.1°C
0.2°F
Humidity resolution :1% R.H.
Barometric Pressure Measurement
Pressure measuring range :750 to 1100 mb/hPa
at 25°C
(22.15 to 32.49 inHg)
Pressure sampling cycle :20 minutes
Moon Phase Functions
Moon Phase Scanner Range :forward/
backward 39 days
Remote unit
Proposed operating range  : -20°C to + 60°C
-4 °F to 140 °F
Temperature resolution  : 0.1°C
0.2°F
RF Transmission Frequency  : 433 MHz
Maximum No. of Remote unit : 3
RF Transmission Range  : Maximum 30 meters
(open area)
Temperature sensing cycle  :around 43~47 seconds
Relative Humidity Measurement
Remote relative humidity :10%RH to 95%RH
measurement range
Resolution :1%RH
UV sensor
Proposed operating range :0.0UVI to 16.0UVI
:0.0 MED/h to
6.9 MED/h
Resolution :0.1UVI / 0.1 MED/h
RF Transmission Frequency :433 MHz
Max. No. of remote unit :1
RF Transmission Range :Maximum 30 meters
:(open area)
UV sensing cycle :5 minutes
Power
Main unit  :use 2 pcs UM-3 or
“AA” 1.5V battery
Remote sensing unit  : use 2 pcs UM-3 or
“AA” 1.5V battery
Weight
Main unit  :335g (without battery)
Remote sensing unit : 62g (without battery)
Remote UV sensor :78g (without battery)
Dimension
Main unit  : 220 x 90 x 33 mm
Remote sensing unit  : 55.5 x 101 x 24 mm
CAUTION
- The content of this manual is subject to change
without further notice.
- Due to printing limitation, the displays shown in
this manual may differ from the actual display.
- The contents of this manual may not be reproduced
without the permission of the manufacturer.
0125
EC-DECLARATION OF CONFORMITY
Product : TE761EL / HBVR761
This product contains the approved transmitter and
complies with the essential requirements of Article 3 of
the R&TTE 1999/5/EC Directives, if used for its
intended use and that the following standard(s) has/have
been applied:
Efficient use of radio frequency spectrum
(Article 3.2 of the R&TTE Directive)
applied standard(s) EN 300 220-1,3:2000
Electromagnetic compatibility
(Article 3.1.b of the R&TTE Directive)
applied standard(s) EN 301 489-1,3:2000
applied standard(s) EN 300 339:2000
Additional information:
The product is therefore conform with the Low Voltage
Directive 73/23/EC, the EMC Directive 89/336/EC and
R&TTE Directive 1999/5/EC (appendix II) and carries
the respective CE marking.
RTTE Compliant Countries :
All EU countries, Switzerland CH
QA MANAGER : H.Y.WANG
K.S plastic factory
Guan Lan / Shen Shen / China
6

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Irox HBVR761 UV-X wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Andere Handbücher von Irox HBVR761 UV-X

Irox HBVR761 UV-X Bedienungsanleitung - Deutsch - 7 seiten


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info