The JA-80V LAN/PSTN line communicator - 9 - MKA51202
5.28. ARC communication checking period
The time to wait after the last report sent to an ARC before performing
an ARC communication check is set by this sequence. The
communication-checking event code is 31 (see 5.26). This sequence
programs how often the communication check is performed:
07 a hhmm
where
a 1 = ARC1, 2 = ARC2
hh hours
mm minutes
Notes:
Checking reports are not sent in service mode
IP CID protocol allows very frequent checking of ARC
communication (e.g. every 5 minutes).
Factory default setting: 24 hours after the last report – for both ARCs
5.29. Enable ARC reporting (ARC2 backs up ARC1)
This sequence allows reporting to ARCs to be switched on/off and also
enables ARC2 to backup ARC1:
00 a x
where
a 1=ARC1, 2=ARC2
x 0=off, 1=on, 2= ARC2 backs up ARC1 (2 can only be
entered for ARC2)
Note: if ARC2 backs up ARC1 then it will only receive data if it is not
possible to deliver it to ARC1. A report containing “Communication
fault to ARC1” is then sent to ARC2 together with the first report to
ARC2.
Factory default setting: both ARCs = off
5.30. Recording reports sent to ARCs in the control panel
memory
This sequence enables the recording of every report successfully
communicated to ARCs in the control panel’s internal memory.
080 enabled
081 disabled
Note: it is recommended not to record reports sent to ARCs but to
enable the indication of ARC communication faults (see 5.31). This
saves a significant amount of control panel memory. The system
initially assumes that every report is successfully delivered to ARCs,
but if a report is not successfully delivered within 110 seconds of
transmission, then a communication fault will be indicated and
recorded.
Factory default setting: enabled
5.31. Indicate an ARC communication fault if a report is not
successfully received within 110 sec of transmission
Enables the indication and recording of a communication fault if a
report is not successfully delivered to an ARC within 110 seconds of its
transmission.
090 communication faults not indicated
091 communication faults indicated
Notes:
The communicator continues trying to send information to an ARC
even after a communication fault has been indicated (after the data
has been delivered, communication fault indication stops).
For communication-checking reports the delivery time limit
(confirmation from the ARC) is 300 minutes. But if any other report is
sent to the ARC it must be confirmed within 110 seconds (otherwise
a communication fault will be indicated)
Factory default setting: communication faults not indicated
5.32. IP address for data transmission
The communicator supports transmission of the special data (e.g.
visual information for the img.jablotron.com ) from the system to set IP
address, which can be set by following sequence:
013 xx..x 0 where:
xxx...x is IP address and port – set in format as shown in the
example:
01 3 8 192 168 021 123 08080 0
8 insert # character, to identify the IP address which must
consist of 12 digits followed by 5 digits of the port
To erase the IP set 0130.
Factory default : IP address is set to 77.104.220.129 7070
(img.jablotron.com)
5.33. Locking the ARC settings
All settings which effect reporting to ARCs can be locked by a digital
code:
901 xx..x 0 where xx..x is an installer-defined locking code (4 to
8 digits)
Notes:
Exiting service mode after the locking code has been entered will
lock all the settings effecting ARC communication (see the
sequence list in section 5).
If ARC programming is locked, then it can be temporarily enabled
in service mode by entering 900 xx..x 0 where xx..x is the locking
code. It will then relock on exiting service mode.
The ARC settings can be permanently unlocked by entering 9010
while ARC programming is temporally enabled – see above. This
will erase the locking code.
Factory default setting: ARC settings unlocked
5.34. Engineer reset
The Engineer reset also requires the control panel firmware to be of
version KE60108 or higher. This feature is designed for ARC (Alarm
Receiving Centre) connection to satisfy the following requirements of
the DD243 standard: After a confirmed alarm has been triggered, the
control panel must switch to a disabled state. Switching to normal
operation is then only possible using a valid ARC access code. Until
then, the system remains completely disabled – no operation or
programming is possible even when in Maintenance or Service
mode.
An ARC access code can be entered:
GSMlink in the field used for remote code entry
SMS instruction
*
ARC-code_instruction
(e.g.
*
12345678 STATUS)
6. LAN network configuration
Each device in an Ethernet network (LAN, internet) has its own IP address
(e.g. 192.168.250.20). This address can either be a public or private one.
Before connecting the LAN network cable, setting up the LAN network
should be done – either by automatic DHCP or manually (see 5.18).
If automatic DHCP is used, contact your network supervisor and ask
him to make the network ready for the communicator. If he needs the
communicator MAC address you will find it on the label attached to the
communicator board.
Manual programming of the network parameters should be done by a
network supervisor who knows how to program these parameters.
7. Further guidance on the communicator
7.1. How the communicator sends reports
If there is a need to report an event (e.g. an alarm) then the
communicator:
sends data to ARC1, if used (the communicator tries the main IP
address, if unsuccessful then it tries the backup IP address).
Then it sends data to ARC2 in the same way if programmed as an
independent ARC. If ARC2 is programmed as the backup to ARC1
then the data will only be sent to it if transfer to ARC1 has been
unsuccessful.
Then the unit sends SMS reports (1
st
tel. number, 2
nd
tel. number ….8
th
tel. number)
Then the unit performs reporting by phone call (1
st
tel. number, 2
nd
tel.
number ….8
th
tel. number) – each programmed number is called once
whether the call has been answered or not
If all previous attempts to send data to ARCs have been unsuccessful,
the next attempts occur after the programmed repeat period (see
5.27).
If an alarm is cancelled by a user while it is being reported, any unsent
SMSes and unperformed call reports are cancelled, but the ARC still
gets a complete set of reports about events in the system.
9

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Jablotron JA-80V - LAN Communicator wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info