7.2. The communicator’s LEDs
Green LED:
regular flashing – communication in progress (ARC, SMS or
remote access)
off – data is waiting to be sent to an ARC
lit permanently – no waiting data to be sent to an ARC
Red LED:
off – communication to the ARC is OK
lit permanently – impossible to send data to any ARC
Yellow LED:
regular flashing – Ethernet connected, DHCP is not working
off – Ethernet is not connected
lit permanently – Ethernet connected and communication with
the network is OK
7.3. After entering service mode the communicator:
finishes reporting to ARCs (if any is needed)
unfinished SMS and call reports are cancelled
unsent ARC reports are only erased if ARC tel. numbers / IP
addresses or the ARC communication format or the installation ID are
changed
alarm restoration reports or fault restoration reports are sent to the
ARC even in service mode
changes to communicator settings do not take effect until service
mode has been exited
7.4. Configuring the communicator in maintenance mode
If configuring the communicator in maintenance mode is enabled (via
control panel programming), then the above described programming
sequences can be used to set:
tel. numbers M1 to M7
the events reported by SMS and phone calls
7.5. Remote access by Internet
The system can be accessed remotely via www.GSMLink.cz
which
allows complete programming by installers and also operating the
system by end users. To access the system remotely it is necessary
to:
Have the communicator connected to an Ethernet network which
allows access to www.GSMLink.cz
Register the communicator via the GSMLink web page by:
o displaying www.GSMLink.cz and selecting New registration
o setting your login details (name and password)
o entering the communicator registration code (see the
communicator label)
o entering your system access code (user or service – this gives
you access to the user menu or the installer menu accordingly)
o after entering the above parameters it should be possible to
establish a connection with the system.
If your communicator is using a dynamic IP address when
communicating with the GSMLink server, then it could be that you
will have to wait for a connection (if your IP address has been
changed). GSMLink will indicate how long it will take to get
connection with the system. To shorten the waiting time it is
possible to initialise the communication remotely by dialling from a
telephone which has been programmed for this function (see
5.10.1).
for further access sessions you only need to enter your login details
(these can be memorized by your web browser)
several people can register for internet access to the system (both
installers and users)
A service technician needs only one set of login details to access
various installations. After the first system has been registered, the
installer can add (or remove) other installations to(or from) his/her
GSMLink account.
there is a demo version of remote access on www.GSMLink.cz
using www.GSMLink.cz
is free of charge
7.6. A complete list of CID reports to ARCs
A report to an ARC consists of: installation ID, event code, subsystem
number and the number of the source (device or code). In IP CID and
SMS CID, in addition to this, a time stamp is also sent as follows.
List of the CID reports
CID code Event ec
1130 / 3130 Intruder alarm – instant / restored 1 / 9
1134 / 3134 Intruder alarm – delayed / restored 2 / 9
1110 / 3110 Fire alarm / restored 3 / 9
1120 / 3120 Panic alarm / restored 4 / 9
1461 / 3461 Number of incorrect code-entries exceeded
alarm / restored
5 / 9
1140 / 3140 Alarm triggered during control panel power-up /
restored
6 / 9
1137 / 3137 Tamper alarm / no tampering 7 / 8
1144 / 3144 Device tamper alarm / no tampering 7 / 8
1406 Alarm cancelled by user 10
1401 / 3401 Unsetting / setting 12 / 11
3402 Partial setting 13
3408 Codeless complete setting 14
1354 / 3354 External communication fault / restored 15 / 16
1300 / 3300 Fault (except device) / all faults restored 17 / 18
1330 / 3330 Device fault / all faults restored 17 / 18
1301 / 3301 Mains dropout longer than 30 minutes /
restored
19, 20 / 21
1302 / 3302 Battery fault (except devices) / all battery faults
restored
22 / 23
1384 / 3384 Device battery fault / all battery faults restored 22 / 23
1306 / 3306 Switching to Service Mode / Leaving Service
mode
24 / 25
1661 / 3661 PGX ON/OFF 26
1662 / 3662 PGY ON/OFF 27
1355 Radio communication jamming present 28
1350 / 3350 Internal communication fault / restored 29 / 30
1602 Communication test 31
1138 Unconfirmed alarm 32
1351 Communication fault to ARC1 to ARC2 if
backups
1393 Annual check request 17
1551 / 3551 Communicator blocked / restored 31 only in
IP CID
List of source numbers
Source
number
Source
701 Control panel
731 Communicator
741 Wired keypad
001 - 050 Devices 01 - 50
500 Master code
599 Service code
501 - 550 Codes 01 - 50
Subsystem: 01 in all reports
In a split system, for setting and unsetting: 02 = A, 03 = B
For partial setting: 02 = A, 03 = AB
8. Technical specifications
Power 12V DC (from the control panel)
Stand-by consumption about 35 mA
Max. consumption (during communication) 1 A
Complies with EN 50131-1/2006, EN 50136-1-1, 2-1 as:
ATS 4 if the ARC comm. repeating period is zero (sequence 06a0)
ATS 5 if ID CID protocol is used and the repeating period is set to zero
(sequence 06a0)
Operating environment ( –10 to 40°C) class II
Safety EN 60950
EMC EN 55022, EN 5030-4
Radio transmissions ETSI EN 301419-1 and EN 301511
CLIP protocol (caller ID + SMS) ETSI EN 300 089 V3.1.1(2000-12)
Jablotron Ltd. hereby declares that the JA-80V is in compliance with
the essential requirements and other relevant provisions of Directive
1999/5/EC.
Jablotron Ltd. hereby declares that the product complies with part 15
of the FCC rules. Operation is subject to the following two
conditions: 1. This device may not cause harmful interference, and 2.
This device must accept any interference received, including
interference that may cause undesired operation.
CAUTION: Changes or modifications no expressly approved by Jablotron could
void the user’s authority to operate the equipment.
The original of the conformity assessment can be found at www.jablotron.com
, -
Technical Support section
Note: Although this product does not contain any harmful materials we
suggest you return the product to the dealer or directly to the producer
after use.
10

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Jablotron JA-80V - LAN Communicator wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info