Initial Delay (INITIAL DELAY)
In order to detect the Signal Pulse from the Brushless motor, it is essential to use ESC, however, certain ESC on
the R/C market o󰮏ers the function to alert initial start with sound of beep. This canbe recognised as a highest
RPM signal on this sensor, So False RPM may appear on the data screen. In order to avoid this false signal
reading, It is capable to set the transmitter to read the signal with some delay between 5seconds to 30seconds
(with 5seconds interval. Initially it is set as INH. Set the required timing by seconds to activate this function.
Altimeter▋(ALTITUDE)
UNIT (SCALE)
This selects the units Meter (m) or Feet (ft). Select the units as
desired.
Sound: Audio (SOUND1,2,3)
It is possible to select from three (3) types of audio for different
altitude indications. Initially it is set to inhibit. If desired, set the alert
sound depending on the situation. It is possible to set altitude between
1 2000m in 1.0 meter increments.
Types of Alert:
: When the altitude is greater than the set value.
: When the altitude is less than the set value.
〜 : When ying within the set altitude range.
When the alert is set in an altitude range, it can be set between 0.3m 〜 9.9m in 0.3m increments.
If the three (3) conditions overlap, Priority is set as “SOUND3 > SOUND2 > SOUND1.
Switch Select (SW SEL)
It is possible to set an Alert to be active by switches or stick position, or a combination of those devices by
using “SW SEL. Initially it is always turned on.
Climb▋Indicator▋(VARIOMETER)
UNIT (SCALE)
This selects the units(m/s, ft/s). Select the units as desired.
Audio for Ascent (UP SOUND1,2,3,4)
The Climb Rate can be set in 4 di󰮏erent ranges, with an alert for each
range. Each one of the setting can have an alert. Initially it is set to
“INH. The Climb Rate alert can be set between 0.1m/s 3.0m/s, in
0.1m/s increments.
If the four (4) conditions overlap, Priority is set as "SOUND4 > SOUND3 > SOUND2 > SOUND1".
Audio for Descent (DOWN SOUND)
The Descent Rate can be set in 4 different ranges, with an alert for each range. Each one of the setting can
have an alert. Initially it is set to “INH”. The Descent Rate alert can be set between 0.1m/s 3.0m/s, in 0.1m/s
increments.
Switch Select (SW SEL)
It is possible to set the Alert to be active by switches or stick position, or a combination of those devices by
using “SW SEL. Initially it is always turned on.
For▋Motive▋Power▋Battery▋(FLIGHT▋PACK)
Motive Power BatteryAlarm (VOLT-ALARM)
It is possible to set an alert for low Motive Power Battery voltage.
Initially it is set as Inhibited. Set the alert voltage as desired. The
Voltage can be set between 0.1V 〜 655.3V in 0.1V increments.
Nominal Capacity Value (CAPACITY)
It is possible to set a Nominal Capacity Value to match your Motive
Power battery capacity. The remaining battery capacity value is
displayed by deducting the consumed capacity value. It can be set
between 0mAh 〜 30,000mAh, in 10mAh increments.
Battery Capacity Alarm (CAPA-ALARM)
It is possible to set a capacity remaining alert based on the Nominal Capacity value of your battery. Initially
it is set as Inhibited. To activate, set a percentage between 0% to 100%. The alarm will sound when this
calculated percent capacity remaining reaches this gure.
Receiver Battery
Voltage
Temperature
Variometer
Motive Power Battery
(Voltage/Capacity)
Rotation Speed
Altitude
System▋List
Receiver Battery
Voltage
Temperature
Variometer
Motive Power Battery
(Voltage/Capacity)
Rotation Speed
Altitude
Receiver Battery
Voltage
Temperature
Variometer
Motive Power Battery
(Voltage/Capacity)
Rotation Speed
Altitude
XG14English.indd 80 2013/07/16 16:41
82

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für JRpropo XG14 wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info