657271
11
Zoom out
Zoom in
Vorherige Seite
1/130
Nächste Seite
– 3
The pump is maintenace-free.
CAUTION
In order to prevent accidents or injuries, keep in mind
the weight of the appliance during transport (see Spec-
ifications).
Lift and carry the pump on the carrying handle.
If you want to transport the appliance on a vehicle
secure it from slipping.
CAUTION
In order to prevent accidents or injuries, keep in mind
the weight of the appliance when selecting a storage lo-
cation for it (see Specifications).
Completely drain the pump and allow it to dry.
Store the pump in a frost-free place.
Maintenance
Transport
Storage
Storing the pump
Special accessories
2.997-100.0 Braided hose set Flexible 1 1/4“ braided hose with hose clamp (30 - 40 mm) with wing
screw for a connection without tools.
Especially recommendable for the immersion pumps when remov-
ing large water quantities.
Max. operating pressure: 5 bar
2.997-201.0 Prefilter for immersion pump,
small
The robust prefilter is easy to attach and protects your immersion
pump, which increases the functional reliability.
6.997-359.0 Pump connection G1 (33.3
mm) incl. Check valve
For pumps with G1 (33.3 mm) connection thread and 3/4" as well as
1" hoses, including union nut, hose clamp, flat packing and check
valve.
6.997-347.0 Spiral hose, by the meter,
25 m, 3/4"
By the meter for cutting hoses to individual lengths.
6.997-346.0 Spiral hose, by the meter,
25 m, 1"
By the meter for cutting hoses to individual lengths.
2.645-142.0 Hose PrimoFlex, 25 m, 3/4" Phthalate-free 3/4" garden hose for draining away the water.
2.645-247.0 Hose PrimoFlex, 50 m, 1" Phthalate-free 1" garden hose for draining away the water.
Troubleshooting
DANGER
Risk of mortal danger on account of electric shock!
To avoid risks, all repairs and replacement of spare parts may only be carried out by the authorised customer service
personnel.
Fault Cause Remedy
Pump runs but does not transport Air in the pump Unplug and plug in the mains plug of
the pump repeatedly until the fluid is
drawn
Suction area blocked Pull out the mains plug and clean the
suction area
(only in manual mode) Water level be-
low the minimum water level
Immerse, whenever possible, the pump
deeper into the feed fluid or proceed as
described in Chapter Operation.
Pump does not run or suddenly comes
to a standstill during operations
Power supply interrupted Check fuses and electrical connections
Thermal protection switch has
switched off the pump due to over-
heating
Pull out the mains plug, let the pump
cool down, clean the suction area,
prevent dry running
Dirt particles have got jammed into the
suction area
Pull out the mains plug and clean the
suction area
The float switch stops the pump Check position of float switch.
Pumping capacity is reducing Suction area blocked Pull out the mains plug and clean the
suction area
Pumping capacity too low The pumping capacity depends on the
flow height, hose diameter and hose
length.
Observe the maximum delivery
height, see technical data. If neces-
sary, use a larger hose diameter or a
shorter hose length.
Quick-Connect cannot be opened or
closed.
Soiling in the plug system. Remove and clean clip.
11EN
11

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln
1

Forum

karcher-sp-2-flat

Suche zurücksetzen

  • Die Pumpe löst einen Kurzschluss aus. Wo ist die Sicherung? Eingereicht am 26-4-2021 17:11

    Antworten Frage melden

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Karcher SP 2 Flat wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info