The only indication that the membranes might benefit from cleaning is a substantial reduction in
the quantity of product freshwater output, all other factors being normal (e.g., battery voltage,
salinity, seawater temperature). The best way to detect such a problem is by keeping an
accurate log of product freshwater output at known battery voltages. Such a practice is highly
recommended.
If you have determined that your membranes need cleaning and you know the type of deposits
(mineral or organic), use the appropriate cleaner. If you do not know the nature of the deposits,
try cleaning first with the
Alkaline Cleaner and check for improvement in product
freshwater output. If output remains poor, repeat the cleaning process using the
Acid
Cleaner
. Never mix the two types of cleaners! Always flush well with clean water between
processes if performing both alkaline and acid cleaning. The following directions apply for both
types of membrane cleaners:
1. Turn the clean/run valve lever on the pump to its “clean” position (see Figure 8).
2. Discard any dirty seawater in the prefilter assembly. Clean the housing and install a clean
element
3. Fill a clean plastic container or bucket with one gallon (approximately 4 liters) of clean
water. Freshwater is preferable, but clean seawater may be used if freshwater is not
available. (Caution: Never use chlorinated freshwater. This may damage the
membrane.)
4. Mix four spoonful (approximately 40 grams) of either Acid Cleaner or Alkaline Cleaner
(not both!) with the water in the container and stir until the cleaner is completely
dissolved. The water should be warm, but not over 120° F (49° C).
5. Turn the lever on the prefilter 3-way valve to the alternate intake position. Run the 1/4"
alternate intake hose with the strainer attached into the container of cleaning solution.
6. Disconnect the reject brine water hose from its drain (or use a separate length of hose) to
route the reject brine water back into the container of cleaning solution during the
following procedure.
7. Turn on the watermaker. Discard any solution coming from the reject brine hose for about
30 seconds. Then run the reject brine water hose back into the container of cleaning
solution to allow recirculation of the cleaner.
8. Continue to run the watermaker for about 15 minutes, to assure that the cleaning solution
is well circulated through the pump and membrane housing.
9. Turn off the watermaker and allow the membranes to soak in the cleaning solution for 5
to 10 hours, or overnight. For severe fouling, repeat Steps 8 and 9 of this procedure.
10. When the soaking is finished, remove the reject brine hose from the cleaning solution
container and run the watermaker again. Discard the first pulses of the reject brine water.
When the reject brine flow becomes cleaner, return the reject brine hose to the cleaning
solution container for recirculation.
11. Continue to run the watermaker and recirculate the cleaning solution for another 30 to 60
minutes
12. When cleaning is complete, turn off the watermaker. Reconnect the reject brine hose to
its normal drain location.
13. Remove the alternate intake hose and strainer from the cleaning solution and place them
into a container of clean, warm (non-chlorinated) freshwater. If freshwater is not
available, clean seawater may be used if its temperature is above 68° F (20° C).
14. Turn on the watermaker and flush warm water through the system for 5 minutes.
If the watermaker will be stored for more than a week (three days in warm climates), it should
now be treated with the membrane preservative solution.
14
18

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Katadyn PowerSurvivor 80E wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Andere Handbücher von Katadyn PowerSurvivor 80E

Katadyn PowerSurvivor 80E Bedienungsanleitung - Deutsch - 36 seiten


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info