771580
12
Zoom out
Zoom in
Vorherige Seite
1/23
Nächste Seite
Installation & Owner's Manual
9
Water Affusion
Hot water outlet
Close
Water out
When water flows out from the water outlet,
the tank is full. Turn off the hot water outlet
valve and water affusion is finished.
Open
Open the cold water inlet valve and the hot
water outlet valve.
Cold water inlet Hot water outlet
Open
Close
Open
Drainpipe shut-off valve
Open
Cold water inlet
Close the cold water inlet valve, open the hot
water outlet valve and open drainpipe.
Hot water outlet
The unit cannot be placed into any type of closet or small
enclosure.
The site location must be free from any corrosive
elements in the atmosphere such as sulfur, uorine, and
chlorine. These elements are found in aerosol sprays,
detergents, bleaches, cleaning solvents, air fresheners,
paint, and varnish removers, refrigerants, and many
other commercial and household products. In addition
excessive dust and lint may affect the operation of the unit
and require more frequent cleaning.
The ambient air temperature must be above -7ºC and
below 43ºC.If the ambient air temperature falls outside
these upper and lower limits the electrical elements will be
activated to meet the hot water demand.
3.4.2 Water System Piping
PTR valve(Temperature and pressure relief valve)
properly installed with a discharge pipe run to an
adequate drain and sheltered from freezing.
All piping properly installed and free of leaks.
Unit completely lled with water.
Water temperature limit valve or mixer tap(recommanded)
installed per manufacturer’s instructions.
3.4.3 Condensate Drain Line Installation
Must be located with access to an adequate drain or
condensate pump.
Condensate drain lines installed and piped to an adequate
drain or condensate pump.
3.4.4 Electrical Connections
The water heater requires 230 VAC for proper operation.
Wiring size and connections comply with all local
applicable codes and the requirements of this manual.
Water heater and electrical supply are properly grounded.
Proper overload fuse or circuit breaker protection
installed.
3.4.5 Post Installation Review
Understand how to use the User Interface Module to set
the various parameters and functions.
Understand the importance of routine inspection/
maintenance of the condensate drain pan and lines.
This is to help prevent any possible drain line blockage
resulting in the condensate drain pan overowing.
IMPORTANT: Water coming from the plastic shroud is
an indicator that both condensation drain lines may be
blocked. Immediate action is required.
To maintain optimal operation check, remove and clean
the air lter.
4. TRIAL-RUNNING
4.1 Water affusion before operation
Before using this unit, please follow the steps below.
Water Affusion: If the unit is used for the rst time or used again
after emptying the tank, please make sure that the tank is full of
water before turning on the power.
Method: see Fig.4-1
Fig.4-1
CAUTION
Operation without water in water
tank may result in the damage of
auxiliary E-heater. Due to such
damage, manufacturer will not be
liable for any damages caused
by this issue.
After powered on, the display lights up. Users can
operate the unit through the buttons under the display.
Emptying: If the unit needs cleaning, moving etc, the
tank should be emptied.
Method: See Fig.4-2:
Solar Pump
(300L)
Alarm
SW1 Factory Setting
for Disinfect
&Electric Heater
Model Selection
SW2 Factory Setting
for 190L/300L Model
Selection
High Pressure
Switch
Tp:Comp
Discharge
Temp.Sensor
Transformer
Output
Transformer
Input
Power Supply
Solar Input
(300L)
Fan COMP 4-way
Valve
EHEAT S.V. Crank
Heater
Panel Display
Power Supply
Output
Panel Display
Output
T5L:Lower
Tank Water
Temp.Sensor
T5U:Upper
Tank Water
Temp.Sensor
T4:Ambient
Temp.Sensor
T3:Evaporator
Inlet Temp.
Sensor
Th:Comp
Suction
Temp.Sensor
L
N
GND
Power Cable
Creepage Protector
Power Supply
EEV
12

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Kaysun COMPAK KHP wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info