Installation & Owner's Manual
17
Anode Rod
P2
High discharge temperature protection
TP>110°C, Protection active
TP<90°C, Protection inactive
Maybe because of system blocked, air or water or
less refrigerant(leakage) in system( after repair), water
temperature sensor malfunction, ect.
Contact a qualied person to service the unit.
P3
Compressor abnormally stopped protection The
discharge temperature is not so higher than evaporator
temperature after compressor running a term.
Maybe because of compressor broken or bad connection
between PCB and compressor.
Contact a qualied person to service the unit.
P4
Compressor overloaded protection (10 secs after
compressor startup, current checking starts , 1)only
compressor running, if it is >10A , the compressor will
be stopped and protected.)
2)Compressor+E-heater running, if it is >IEH+10,the
compressor will be stopped and protected.)
Maybe because of compressor broken, system blocked,
air or water or more refrigerant in system(after repair),
water temperature sensor malfunction, ect.
Contact a qualied person to service the unit.
LA
When the ambient temp T4 is out of Heat Pump running
range (-7°C~43°C) Heat Pump will stop, unit will show
LA on the position of clock on display until T4 back to
(-7°C~43°C).
Only valid for the unit without E-heater.
Unit with E-heater will never show "LA".
It is normal, and no necessary to repair.
NOTE
The diagnostic codes listed above are the most common.
If a diagnostic code not listed above is displayed, contact
residential technical assistance referenceing the number on
the front of this manual.
If any of P1/P2/P3/P4 continuously appear 3 times within
single heating cycle, system will consider it as “Heat Pump
system error”. The third failure code and will be shown
on the display, then heat pump will stop running, and the
unit will shift automatically to active E-heater as the backup
heat source, but the third failure code and will be shown
until power is reset. Contact a qualified person to service
the unit.
7. MAINTENANCE
7.1 Maintenance
1) Check the connection between power supply plug and socket
and ground wiring regularly;
2) In some cold area (below 0°C), if the system will be stopped for
a long time, all the water should be released in case of freezing
of inner tank and damage of E-heater.
3) It is recommended to clean the inner tank and E-heater every
half year to keep an efcient performance.
4) Check the anode rod every half year and change it, if it has
been used out. For more details, please contact the supplier or
the after-sale service.
5) It is recommended to set a lower temperature to decrease the
heat release, prevent scale and save energy if the outlet water
volume is sufcient.
6) Clean the air lter every month in case of any inefciency on
the heating performance.
In terms of the filter set in air inlet directly (namely, air inlet
without connect with duct), the method of dismantle the lter is:
anti-clockwise unscrew the air inlet ring, take out the lter and
clean it completely, nally, remount it to the unit.
7) Before shutting the system off for a long time, please:
Shut off the power supply;
Release all the water in water tank and the pipeline and close
all the valves;
Check the inner components regularly.
8) How to change the anode rod
Turn off the power, and turn off the water inlet valve.
Open hot water tap, and decrease the pressure of the inner
container.
Open the drainage valve, and drain out the water, until there are
no water ow out.
Get off the anode rod.
Replace with a new one, and make sure effective sealed.
Open cold water inlet tap untill water ows out from outlet tap,
then turn of water outlet tap.
Power on then restart the unit.
Fig.7-1
7.2 Recommended regular maintenance table
Table.7-1
Checking Item Checking content Checking
frequency Action
1air lter (inlet/
outlet) every month Clean the lter
2anode rod every half year
Replace it if it
has been used
out
3inner tank every half year Clean the tank
4E-heater every half year Clean E-heater
5
PTR valve every year
Operate the
hander of PTR
valve to ensure
that waterways
are clear.
If water doesn't ow freely when operating the
hander, replace PTR valve with a new one.
20

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Kaysun COMPAK KHP wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info