606692
92
Zoom out
Zoom in
Vorherige Seite
1/96
Nächste Seite
84
15 TROUBLESHOOTING
OPERATION NOTICES
The transceiver has been designed and engineered to
avoid possible hardware glitches. However, you may
notice the following symptoms when you operate the
transceiver. These symptoms are not malfunctions.
DC POWER SUPPLY
As stated in the SPECIFICATIONS {page 80}, this
transceiver requires a supplied DC voltage source of
13.8 V ±15%. If you fi nd that the transceiver cannot
be switched ON, or that it shuts OFF automatically, the
DC voltage may be outside the specifi ed range.
In such a case, remove the DC cable from the
transceiver immediately and confi rm that the supplied
voltage is within the specifi ed range.
INTERNAL COOLING FAN
The transceiver detects the temperature of the
nal department regardless of the transmission
and reception state of the main body, in order to
protect the internal circuits from high temperatures.
The cooling fan speed and transmission output is
controlled through the following.
When the thermistor detects a rise in temperature
in the fi nal department, the cooling fan turns on at
low speed. As the temperature rises, the speed of
the cooling fan increases.
When an abnormally high temperature is detected,
the temperature protection circuit activates,
reducing the transmission output to the lowest
possible power.
When the temperature protection circuit activates,
return the transceiver to receive mode and leave the
transceiver power ON. Allow time for the cooling fan
to return the internal temperature to normal.
If you turn the transceiver power OFF, the cooling
fan will not run and it will take much longer for the
internal temperature to decrease.
INTERNAL BEATS
On some spots of the receiver frequencies, the
S-meter moves or you cannot receive any signals.
This is inevitable when you use superheterodyne
receivers. You may notice the signals on the following
spots of the frequency:
• 15.600.00 MHz
• 31.200.00 MHz
• 46.800.00 MHz
AGC
When you turn the AGC function OFF {page 30}, the
receiving audio signals can be distorted. In this case,
decrease the RF gain, turn the pre-amplifi er OFF, or
turn the attenuator ON. In general, the RF gain must
be greatly reduced when the AGC is turned OFF.
60 m BAND OPERATION
Effective from July 3, 2003, FCC Report and Order
(R&O) in ET Docket 02-98 granted US amateurs
secondary access to fi ve discrete channels in the
vicinity of 5 MHz. General, Advanced, and Amateur
Extra licensees may use the following fi ve channels
on a secondary basis with a maximum effective
radiated power of 50 W PEP relative to a half wave
dipole. Only upper sideband suppressed carrier voice
transmissions may be used. The frequencies are
5330.5, 5346.5, 5366.5, 5371.5 and 5403.5 kHz. The
occupied bandwidth is limited to 2.8 kHz centered on
5332, 5348, 5368, 5373, and 5405 kHz respectively.
The TS-590SG transceiver stops at the 60 m band
as you scroll up or down the amateur radio frequency
bands. For more information, contact ARRL or search
their Web site using the key word “60 meter”:
http://www.arrl.org
92

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Kenwood TS-590SG wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Andere Handbücher von Kenwood TS-590SG

Kenwood TS-590SG Bedienungsanleitung - Deutsch - 96 seiten

Kenwood TS-590SG Bedienungsanleitung - Holländisch - 96 seiten

Kenwood TS-590SG Bedienungsanleitung - Französisch - 96 seiten


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info