10 SCAN
MEMORY SCAN
Memory Scan scans all memory channels containing
data (All-channel Scan) or only a group of channels
specified by you (Group Scan). This type of scan
always ascends up through the channel numbers; the
direction of scan cannot be changed. While scanning, if
you want to skip over some programmed channels, turn
the M.CH/VFO.CH control. Pressing Mic [UP] or
[DWN] will also skip over channels but only during
All-channel Scan.
All-channel Scan or Group Scan can be selected via
Menu No. 66 (GRP.SCAN). The default is All-channel
Scan (OFF).
The following are additional important points regarding
the Memory Scan function:
Starting a transmission by closing the CW key, by
sending a packet, or by triggering the VOX circuit by
voice or the DRU-3 Digital Recording Unit stops
Memory Scan; however, transmission does not
begin immediately.
Starting the Memory Scan function switches OFF the
RIT and XIT functions. RIT and XIT are not
switched ON again when Memory Scan stops, and
the RIT/XIT offset frequency is not cleared.
•Attempting to use Memory Scan when no data has
been programmed in any memory channels, or
when all channels are locked out, causes an alarm.
Scan will not start.
•To scan channel 99, cancel Memory Channel
Lockout {page 62} for that channel.
Note:
Remember to adjust the squelch threshold level {page 19}
before using Memory Scan.
BUSY FREQUENCY STOP
The transceiver automatically stops Memory scanning
when a signal is detected if Busy Frequency Stop is ON.
The transceiver remains on the same channel for either
a short time or until the signal drops depending on
which Scan Resume method is selected (see below).
The squelch must be adjusted to the noise threshold
point with no signals present for Busy Frequency Stop
to work.
Toggle Busy Frequency Stop OFF or ON via Menu
No. 67 (BSY.STOP). The default is ON.
Note:
Busy Frequency Stop cannot be used with Program Scan.
Scan Resume Methods
Scan Resume controls when the transceiver
continues Memory scanning after stopping due to a
busy channel. Neither of the following two modes
function if Menu No. 67 (BSY.STOP) is switched
OFF. These modes cannot be used with Program
Scan.
Time-operated mode: After stopping, Scan checks
the busy channel approximately three seconds later.
If the channel is still busy, Scan waits another three
seconds then resumes scanning. If the channel is
not busy three seconds after stopping, Scan
resumes immediately.
Carrier-operated mode: Scan resumes
approximately two seconds after the signal drops.
Select your preferred Scan Resume method via
Menu No. 68 (CAR.SCAN). The default is
Time-operated (OFF).
ALL-CHANNEL SCAN
The All-channel Scan function scans all memory
channels containing frequency data.
1 Recall a Conventional memory channel.
2 Switch OFF Menu No. 66 (GRP.SCAN).
3 Adjust the SQL control while no signal is present.
The squelch must be closed before scanning
starts.
4 Press [SCAN] to start scanning.
5 To stop scanning, press [SCAN], or [CLR],
or [SEND], or Mic [PTT].
67

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Kenwood TS-870S wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Andere Handbücher von Kenwood TS-870S

Kenwood TS-870S Bedienungsanleitung - Holländisch - 102 seiten

Kenwood TS-870S Bedienungsanleitung - Französisch - 102 seiten


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info