Copying Equalizer Data
The customized equalizer characteristics can be copied to one of
the options from “User 1” to “User 3”.
1
Press and hold F [RX EQ] to display the RX
Equalizer configuration screen.
2
Press F2[ ] / F3[ ] to select the equalizer to
save.
Pressing F4 [ADJ] on the RX Equalizer screen displays the RX
Equalizer Adjustment screen. Equalizer data can be copied from
either the RX Equalizer screen or RX Equalizer Adjustment screen.
3
Press F5 [COPY].
A message appears prompting you to confirm the destination
to copy the equalizer characteristics.
Pressing F7 [CANCEL] ends the equalizer data copy
operation without copying and restores the display to the RX
Equalizer screen or RX Equalizer Adjustment screen.
.
4
Press F2 [USER 1], F3 [USER 2] or F4 [USER 3] to
specify the destination to copy the data to.
The equalizer selected in step 2 is copied to “USER 1”, “USER
2” or “USER 3”.
After copy is complete, the message to confirm the
destination for copying the equalizer characteristics
disappears and the display is restored to the RX equalizer
screen or RX equalizer adjustment screen.
5
Press and hold F [RX EQ] or press [ESC] to end the
process.
Saving Equalizer Data
Multiple sets of customized DSP equalizer settings data can be
created and saved.
Before doing so, configure the destination for saving the data in
File Storage Location of the USB/File Management Menu” to
“Internal Memory” or “USB Flash Drive”. (See 11-2)
To save the data to a USB flash drive, insert a USB flash drive
formatted using this transceiver into (USB-A).
1 Press and hold F [RX EQ] to display the RX
Equalizer configuration screen.
2
Press F2[ ] / F3[ ] to select the equalizer to
save.
3 Press F7 [SAVE].
A message indicating that saving is complete is displayed.
.
4 Press F4 [OK].
5 Press and hold F [RX EQ] or press [ESC] to end the
process.
The saved file is named in the “yyyymmdd_hhmmss”
format. The extension of the saved file is “equ”.
(Example) If the date is 10:20:30 a.m., February 15, 2018:
20180215_102030.equ
The name of the destination folder is as follows. (The
name varies depending on the destination for saving
files.)
USB flash drive: “KENWOOD\TS-890\SETTINGS
\RX_EQ”
Built-in memory: “SETTINGS\RX_EQ”
When removing the USB flash drive, make sure to
execute “Safely Removing the USB Flash Drive
(11-6).
Reading Equalizer Data
RX DSP equalizer data that is saved in the internal memory or USB
flash drive can be read.
To read the data from a USB flash drive, insert the USB flash
drive containing the RX equalizer data into (USB-A).
1 Press and hold F [RX EQ] to display the RX
Equalizer configuration screen.
2
Press F2[ ]/ F3[ ] to select the equalizer to
read.
3 Press F6 [READ] to display the screen for selecting
the file to read.
.
4 Select the file to read.
To read data from the internal memory, press F7 [INT.MEM].
To read data from the USB flash drive, press F7
[USB.MEM]. (If a USB flash drive is not connected, a message
screen will appear prompting you to get ready the USB flash
drive.)
Pressing F5 [NAME] allows the file name to be changed.
Pressing F6 [DELETE] displays a message to confirm
deletion of the file. Pressing F4 [OK] deletes the file.
5
Press F2[ ]/ F3[ ] to select the RX equalizer
data file to read.
Alternatively, the RX equalizer data file can also be selected by
turning the [MULTI/CH] control.
6 Press F4 [OK].
After the RX equalizer data has been read successfully, a
message indicating that reading is complete is displayed.
7 Press F4 [OK] again.
8 Press and hold F [RX EQ] or press [ESC] to end the
process.
COMMUNICATING AIDS 5
5-5
61

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Kenwood TS-890S wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Andere Handbücher von Kenwood TS-890S

Kenwood TS-890S Bedienungsanleitung - Deutsch - 196 seiten

Kenwood TS-890S Bedienungsanleitung - Holländisch - 196 seiten


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info