3 Use the function keys, [MULTI/CH] control or USB
keyboard to enter a character string.
Key Behavior
F1 [SPACE] Inserts a space.
F2 [–]/ F3 [+] Selects a character.
F4 [ ]/ F5 [ ]
Moves the cursor.
F [BACK SPACE]
Deletes the character to the left of the
cursor.
F [DEL]
Deletes the character to the right of the
cursor.
F [CHAR]
Switches the type of character to edit.
Pressing the key each time switches the
selection in the following sequence:
ABC (upper case) → !”# (symbols) →
ABC (upper case)
4 Press F6 [SAVE] to save the administrator ID and
password.
Each of the ID and password must not be longer than 32
characters.
When the KNS Operation is ON, the KNS “Administrator
ID” and “Administrator Password” cannot be edited or
reset.
Built-in VoIP Function
Follow the steps below to configure whether to use the built-in VoIP
function for voice communication between the remote PC and
transceiver during KNS operation.
Set this function to ON (default setting) to use the built-in VoIP
function for voice communication between the remote PC and
transceiver. Set this function to OFF when using ARVP-10 or a
non-KENWOOD VoIP software program.
1
Select KNS Menu [3] Built-in VoIP.
2 Press F4 [SELECT].
3 Press F2 [–]/ F3 [+] to select “On” or “Off”.
Setting Value Off/ On (default)
When the setting is changed while a connection is
established (logged in), the new setting will be applied
at the next connection.
When using the built-in VoIP, check the following
settings as well. For more details, please refer to the
“TS-890S KENWOOD NETWORK COMMAND
SYSTEM Setting Manual”.
Check that the TX operation setting in the modulation
line selection for ARCP-890 matches the audio input
of the modulation line configured on this transceiver.
Check that audio input of the modulation line
configured on this transceiver in the “Switching the
Audio Source Input” (8-1) section matches the TX
operation setting selected in the modulation line
selection for ARCP-890.
Audio Input/Output Level of Built-in VoIP
The audio input and output level when using the VoIP can be
adjusted as follows. Use the default setting under normal
circumstances.
1
Select KNS Menu [4] Audio Input Level (VoIP) and
KNS Menu [5] Audio Output Level (VoIP).
2 Press F4 [SELECT].
3 Press F2 [–]/ F3 [+] to select the level.
Setting Value
0 to 50 (default: Menu 4) to 100 (default: Menu
5) (1 step)
Built-in VoIP Jitter Absorption Buffer
Follow the steps below to adjust this item when there is a problem
with the voice quality of VoIP. Selecting a shorter time reduces the
audio delay but noise is more likely to occur due to missing audio
packets or the like. Selecting a longer time increases the audio
delay but noise occurrence due to missing audio packets or the
like is potentially reduced. Set the value as small as possible within
a range that does not affect the operation.
1
Select KNS Menu [6] VoIP Jitter Buffer.
2 Press F4 [SELECT].
3 Press F2 [–]/ F3 [+] to select a jitter absorption time.
Setting Value 80 (default)/ 200/ 500/ 800 [ms]
When the setting is changed while the built-in VoIP is in
use, the new setting will be applied the next time VoIP is
used.
Prohibition of Remote Volume Control
This is the function to mute the speaker of the transceiver during
remote operation via KNS.
Use this function during remote operation to stop the audio output
from the speaker of the transceiver.
1
Select KNS Menu [7] Speaker Mute.
2 Press F4 [SELECT].
3 Press F2 [–]/ F3 [+] to select “On” or “Off”.
Setting Value Off (default)/ On
15 NETWORK/KNS OPERATION
15-4
156

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Kenwood TS-890S wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Andere Handbücher von Kenwood TS-890S

Kenwood TS-890S Bedienungsanleitung - Deutsch - 196 seiten

Kenwood TS-890S Bedienungsanleitung - Holländisch - 196 seiten


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info