508541
10
Zoom out
Zoom in
Vorherige Seite
1/31
Nächste Seite
18
Kränzle technology
The thermostat controls the spray water
temperature.
After you switch on the device, "888"
appears in both displays for approx. 1
second as a test of the functioning of the
displays.
Thermostat
12 3 4 5 6
The thermostat has two operating modes:
1. Temperature mode
This mode is always activated when the unit is switched on or can be selected using
the "°C°" button (Pos. 3). The red LED above the "°C" button and next to the set
temperature display lights up. The desired "Set" temperature is set using the two buttons
(+/-, Pos. 5+6) and can be read in the upper display (Pos. 1). If you press the button for a
longer time, the set temperature is quickly adjusted in 5°C increments.
The last set value set is also stored after the unit is switched off and is available again
immediately after switching back on.
The current spray temperature can be read from the bottom display (Pos. 2).
2. Percentage mode
This mode is activated by pressing the "%" button (Pos. 4). The yellow LED above the
"%" button and next to the set temperature display ashes.
In the temperature control system in conventional high pressure cleaners, and in
temperature mode for this unit, the water temperature is measured at the outlet of the
heater, and the heater is switched on an off according to the temperature desired by the
user. Due to the large amount of water in the heating coil, it takes a long time until the
temperature sensor registers that the burner has switched on and the desired temperature
has been reached. This means that the temperature increases far above the desired value
or falls far below the desired value.
19
Thermostat - Percentage mode
The innovative new percentage mode now lets the user specify the switching duration
of the heater in percent using the "+" and "-" buttons (Pos. 5+6) (100% being the max.
temperature) rather than setting the desired temperature. Now the result of the setting
must be checked by using the "Actual" temperature display. If the desired temperature has
not yet been reached, the percentage must be increased.
By setting percentages of the heating duration, the temperature of the high pressure jet is
kept constant in a very narrow range.
The last value set is also saved after the unit is switched off in percent mode.
Operating hour meter
The cleaner is equipped with an operating hour meter.
If during normal operation the momentary operating mode button ( "°C" or "%" ) is actuated for
more then 2 seconds, the operating time of the pump is displayed for 5 seconds and afterwards the
combustion time for 5 seconds as well. Thereafter the display shows the original values again.
As long as the operating hours are displayed no further inputs on the monitor are possible.
The operating time is displayed in hours [ h ] either in the “TARGET” or in the „ACTUAL“
window. The 1000 and 100 hours are displayed in the „TARGET“ window and the 10, 1 and
1/10 hours in the “ACTUAL” window:
Pump operating time: Target-Display: P 9 9 Actual-Display: 9 9. 9 for 9 999.9h
Combustion time: Target-Display: F 9 9 Actual-Display: 9 9. 9 for 9 999.9h
e.g.: F00 27.3 = Cumbustion time 27 hours and 18 minutes
Displayed malfunctions
Anzeige im Feld
Ursache Abhilfe
SOLL IST
Err OFF
Wassertemperatur am
Ausgang der Heizelemente
über 147 °C
Gerät ohne Heizung „Heizung AUS“
so lange betreiben, bis die Temperatur
wieder unter 147°C gefallen ist.
Hauptschalter „AUS“ und wieder „EIN“
schalten
AUS E7
Gerät wurde länger als 20
Minuten nicht betrieben
-> Sicherheitsabschaltung
Hauptschalter „AUS“ und wieder „EIN“
schalten
.
Err E2 Temperatursensor defekt Temperatursensor ersetzen
10

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Kranzle Therm 602 E-M 36 wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Andere Handbücher von Kranzle Therm 602 E-M 36

Kranzle Therm 602 E-M 36 Bedienungsanleitung - Deutsch - 60 seiten


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info