Decommissioning - frost protection
01. Switch off the machine - main switch to „0“- position
02. Cut off the water supply
03. Open the spray gun briefly until the pressure is released
04. Apply the safety catch on the spray gun
05. Remove the water hose and spray gun
06. Drain the pump: switch on the motor for approx. 20 seconds
07. Pull the plug from the socket
08. Clean HP hose and stow away
09. Clean water filter
Frost protection
The machine is normally still partially filled with water after work has been completed.
To protect the appliance from frost, completely empty it of water:
Disconnect the machine from the water supply and switch off the ignition. Switch on the
master switch and open the gun. The pump now presses the remaining water out of the
water tank, the pump and the continuous-flow heater.
Do not allow the machine to run for longer than a minute without water.
If the machine is not in use for lengthy frosty periods of time, it is advisable to pump
anti-freeze into the machine: For this purpose, fill the antifreeze agent into the water
tank and switch on the machine without ignition. Wait with opened gun, until the agent
comes from the nozzle.
However, the best protection against frost is to keep the machine in a place that is
safe from frost.
23
Change the oil:
First oil change after approximately
50 operating hours. Thereafter the oil
should be changed every 500 operating
hours or yearly.
Take the oil drainage hose, which is
connected to the oil drainage screw from the
inside of the appliance.
Open the red oil ller plug at the top side of
the black oil housing.
Open the cap at the end of the hose. Drain
off the oil into an oil pan and dispose of it
responsibly. Close the end of the hose. Rell
with new oil. Oil grade Castrol 10/W-60,
approx. 0.8 l.
Weekly, or after approx. 40 hours of operation:
- Check the oil level of the high pressure pump. If the oil level is too low, add oil until
the oil level is between the two markings on the oil measuring rod.
Change the oil if it has a grey or whitish appearance. The oil should be
disposed of responsibly.
- Check the water filter in front of the float valve in the water tank and the fuel filter
in front of the solenoid valve. Clean the filters if necessary.
Yearly, or after approx. 500 hours of operation:
- Check and decalcify continous flow heater, if necessary.
- Change the oil
Oil leakage: If oil leaks out, go to the nearest customer service
(dealer) immediately. (Environmental damages, transmission damages)
In case of increased humidity or fluctuations in temperature
development of condensed water is possible; if the oil turns grey, you
must change it at once.
Care and Maintenance
The machine must be disconnected from the power supply when
servicing work is being carried out. The main switch should be in
position "0" and the plug out of the socket.
12

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Kranzle Therm 602 E-M 36 wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Andere Handbücher von Kranzle Therm 602 E-M 36

Kranzle Therm 602 E-M 36 Bedienungsanleitung - Deutsch - 60 seiten


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info