lares 4.0 PROGRAMMING MANUAL
49
rev. 0/2018
Type: Reader
The subtypes available are:
• Green LED: sends a message when the green LED is selected on the reader.
• Red LED: sends a message when the red LED is selected on the reader.
• White LED: sends a message when the white LED is selected on the reader.
• Blue LED: sends a message when the blue LED is selected on the reader.
• Yellow Led: sends a message when the yellow LED is selected on the reader.
Type: Communication
The subtypes available are:
• Start of communication: sends a message when the control panel starts a PSTN/GSM/e.mail call, etc.
• Communication failure: sends a message when the control panel fails a PSTN/GSM/e.mail call etc.
• Incoming call: sends a message when the control panel receives a call.
• C-ID communication performed: sends a message when the control panel makes a call using the Contact-ID protocol.
• C-ID communication performed: sends a message when the control panel makes a call using the Contact-ID protocol.
• SIA communication executed: sends a message when the control panel makes a call using the SIA protocol.
• SIA communication failure: sends a message when a call made using the SIA protocol was unsuccessful.
The "entity" section indicates the recipients who receive the call. For example, if in "entity" we have selected the office
user (previously programmed on the "Users" page) and subtype "failed communication ", the control panel will send a
message (to the recipients in the "contact list" ) with an event of failed communication if the call to "office" fails.
Type: Power supply
The subtypes available are:
• Low power supply: sends a message when power is missing on the "lares 4.0" control panel, the wireless duo repeater
or the "opis" power supply station.
• Power recovery: sends a message when power is restored on the "lares 4.0" control panel, the wireless duo repeater
or the "opis" power supply station.
• Low battery: sends a message when the battery voltage drops below the threshold (<11V) (in the absence of the
network)
• Low battery reset: sends a message when the battery voltage is restored following the return of the 230V mains
voltage.
• Battery fault: sends a message when the "lares 4.0" control panel, the imago siren, a wireless device and the "opis"
power supply station fail the battery test.
• Low output: sends a message when the voltage supplied by the "lares 4.0" control panel falls below the threshold
(<14.4V), or when the "opis" power supply station falls below the threshold (<13.1V).
• Low output reset: sends a message when the voltage supplied by the "lares 4.0" control panel is restored above the
threshold value (> 14.4V) or when the voltage supplied by the "opis" power supply station is reset above the threshold
value (> 13.1V).
• Faulty battery charger: sends a message when the power supply of the "lares 4.0" control panel or the "opis" power
supply station fails and does not manage to supply the necessary current to the system.
• Battery charge reset: sends a message when the power supply of the "lares 4.0" control panel or the "opis" power
supply station returns to normal operation or it is replaced.
• Fuse Fault: sends a message when the fuse on the "lares 4.0" control panel or the "opis" power supply station is
detected ( e.g. due to a short circuit).
• Fuse failure reset: sends a message when the fuse on the "lares 4.0" control panel or the "opis" power supply station
restores its operating condition.
Note: if the CPU window appears in the entity window, the events that generate the communication refer to the
"lares 4.0" panel.
49

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Ksenia Lares 4.0 wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info