To wall mount, use the 2 screws to affix the wall bracket to the desired wall, plug in the thermo-
hygro sensor to the bracket and secure both parts by the use of the supplied screw and ensure
that the cables from the wind and rain sensors are correctly plugged in otherwise data
transmission errors could occur.
The Wind Sensor
First, check that the wind-cups and the wind-vane can rotate freely before fixing the unit. For
correct and accurate readings, it is important to mount the sensor so that the front (marked E) is
pointing in East-West direction. The wind sensor should now be mounted using the screw or
cable tie(Remove Cable tie as it leads to sensors falling) provided onto a solid wall/ panel mast
or mast to allow the wind to travel around the sensor unhindered from all directions (ideal mast
size should be from diameter 0.62” to 1.29” (16mm to 33mm). Do not over tighten.
Once the wind sensor is fixed onto the mast, connect the cable to the corresponding thermo-
hygro sensor socket so that operating power supply can be received and data can be transmitted
to the base station. Please note if the wind cord is disconnected for the Thermohygro sensor
Vertical
mast
Wind fan
Horizontal panel
Wind
vane
54
during installation, a complete setup of al units will need to be done. Secure cord from blowing.
Do not use staples. Using PVC pipe or metal as a mast may cause static. Wood is recommended.
The Rain Sensor
For best results, the rain sensor should be securely mounted onto a horizontal surface about
39.37” (1 meter) above the ground (or higher) and in an open area away from trees or other
coverings where rainfall may be reduced causing inaccurate readings.
When securing into place, check that rain excess will not collect and store at the base of the unit
but can flow out between the base and the mounting surface (test by pouring clean water).
After mounting the rain sensor and placing battery, the rain sensor is now operable. For testing
purposes, very slowly pour a small amount of clean water into the rain sensor funnel. The water
will act as rainfall and will be received and displayed at the base station i.e. when the reading
interval is reached.
Note:
You will need to be able to access your rain gauge periodically to clean debris and possible
insect nests. Please keep this in mind when mounting.
Horizontal panel
55
LA CROSSE TECHNOLOGY SENSOR EXTENSION CABLE
When you require additional length to properly mount your sensor, you can use a La Crosse
Technology extension cable. The extension cable is 32 feet in length and comes with the
appropriate connecter attached. Please visit your local retailer or www.greatbigoutlet.com
to
purchase.
Phone cable and connections have much more resistance than our extension cable and is not
recommended for use. Using phone cable/connection may damage your sensors.
Note: Using extension cables will shorten battery life.
Warning: Never cut, splice, shorten or modify your sensor cables or extension cables. Doing so
may damage your sensors and will void you Warranty.
CARE AND MAINTENANCE:
Extreme temperatures, vibration and shock should be avoided as these may cause
damage to the unit and give inaccurate forecasts and readings.
Precautions shall be taken when handling the batteries. Injuries, burns, or property damage
may be resulted if the batteries are in contact with conducting materials, heat, corrosive
materials or explosives. The batteries shall be taken out from the unit before the product is
to be stored for a long period of time.
Immediately remove all low powered batteries to avoid leakage and damage. Replace only
with new batteries of the recommended type.
When cleaning the display and casings, use a soft damp cloth only. Do not use solvents or
scouring agents as they may mark the LCD and casings.
Do not submerge the unit in water.
Special care shall be taken when handling a damaged LCD display. The liquid crystals can
be harmful to user's health.
56
Do not make any repair attempts to the unit. Return them to their original point of purchase
for repair by a qualified engineer. Opening and tampering with the unit may invalidate their
guarantee.
Never touch the exposed electronic circuit of the device as there is a danger of electric
shock should it become exposed.
Do not expose the units to extreme and sudden temperature changes, this may lead to
rapid changes in forecasts and readings and thereby reduce their accuracy.
SPECIFICATIONS:
Temperature measuring range:
Indoor : 32°F to +139.8°F with 0.2°F resolution
0ºC to +59.9ºC with 0.1ºC resolution
(“OF.L” displayed if outside this range)
Outdoor / dew point : -40°F to +139.8°F with 0.2°F resolution
-40ºC to +59.9ºC with 0.1ºC resolution
(“OF.L” displayed if outside this range)
Relative humidity measuring range:
Outdoor : 1% to 99% with 1% resolution
(“- -” displayed if < 1%, "99" displayed if 99%)
Wind speed/ gust : 0 to 111.8 mph (0 to 50 m/s)
(displayed "OF.L" when > 111.8 mph; 50m/s)
Wind chill/ dew point: -40°F to +139.8°F (-40ºC to +59.9ºC)
(displayed "OF.L" if outside this)
Relative pressure pre-set range : 27.14 to 31.90 inHg (919 to 1080 hPa)
24h rainfall : 0" to 39.36" (0 to 999.9 mm)
(displayed "OF.L" when > 999.9mm)
14

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für La Crosse WS-1516-IT wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info