626737
12
Zoom out
Zoom in
Vorherige Seite
1/12
Nächste Seite
Furthermore most of these devices allow the change to an interference-free frequency.
Such measures will effectivelly overcome interferences.
Remote Sensor does interfere with other devices in the 433MHz range.
The transmissions of the Remote Outdoor Sensor can temporarily (for about 200 ms
every 3 minutes) interfere with other devices working on the same channel. These
interferences are of very short duration and can thus be neglected. If possible, the
channel should be changed at the respective device.
15. Transmission Range
The transmission distance in open field with free range of sight between transmitter and
receiver reaches under optimum conditions 330 ft (100 m). Walls and even steel concret
constructions will be penetrated at a considerable loss of transmission distance. A loss of
distance can have the following reasons:
- High frequency interferences of any kind.
- Constructions of any kind or vegetation.
- Especially for the Wind Sensor the transmission distance can be influenced by metal
roofs or aluminum foil roof isolation.
- The distance of transmitter and receiver to conducting planes or object (including the
human body or the ground) does influence the transmission characteristics and thus
the transmission distance.
- Broad band interferences in municipal areas can reach levels reducing the
signal/noise ratio over the entire frequency band, thus also reducing the
transmission distance.
- Devices working at closely neighbouring frequencies may also influence reception.
- Poorly shielded PCs can irradiate the receiver and thus reduce transmission
distance.
- For extension of transmission distance the optionally available Repeater (WS-7015-
12) can be used.
16. Cleaning and Maintenance
- Clean the housing and screen of the Base Station only with a soft, damp cloth. Do
not use abrasives or solvents.
- Ensure that the Remote Rain Volume Sensor does not collect leaves or other dirt.
Remove the funnel from the Rain Sensor every now and then and clean it under
running water. Also clean the seesaw of the sensor with a damp cloth and check by
lightly tapping with your finger that it can move freely from side to side.
Do not clean the funnel with attached bottom part of the Rain Sensor nor the bottom
part itself under running water. This may bear the danger of water entering the unit’s
electronic parts.
- Do not immerse the Base Station in water.
- Please do not attempt any repairs on your own. It is recommended to have repairs
only performed by trained personnel at the point of purchase. Opening or improper
handling of the units will void the warranty.
17. Disposal
If the Professional Remote Weather Station happens to become inoperable and must be
disposed of please do this in accordance with the valid legal regulations.
18. Specifications
Measuring Interval Outdoor Sensor:………………… Appr. 3 minutes
Measuring Interval Indoor Sensor:………………….. Appr. 3 minutes
Transmission Frequency:…………………………….. 433.92MHz
Transmission Distance in Open Field:………………. 330 ft max. (100 m max.)
Temperature Range Indoor:………………………….. 32ºF to 158ºF (0°C to +70°C)
Temperature Range Outdoor:……………………….. -22ºF to 158ºF (-30.0°C to +70°C)
Resolution:………………………………………………0.1ºF (0.1°C)
Accuracy:……………………………………………….. ±2º (±1°C)
Measuring Range Rel. Humidity:…………………….. 20% to 95%
Resolution:………………………………………………1%
Accuracy:……………………………………………….. 8%
Measuring Range Air Pressure:…………………….. 23.62 to 32.48 inHg
(800 to 1100 hPa)
Resolution:………………………………………………0.03 inHg (1 hPa)
Accuracy:……………………………………………….. ±0.03 inHg (±1 hPa)
Air Pressure Variation:…………………………………Bar Diagram, Scaling 2 hPa/
1,5 mmHg per Divider
Rain Volume Display:…………………………………..0 to 157.4 in (0 to 3999 mm)
Resolution:………………………………………………<0.02 in (< 0.5 mm)
Accuracy:………………………………………………. 0.04 in (2%±1 mm)
Wind Strength:…………………………………………. 0 to 124 mph (0 to 200 km/h)
Resolution:………………………………………………0.1 mph (0.1 km/h)
Accuracy:……………………………………………….. 0.6 mph (3%±1 km/h)
Wind Direction:………………………………………… Grafical Resolution 22.5 Degrees,
Numerical Resolution 5 Degrees
Power Supply Base Station:…………………………. 4 x Type Mignon AA, IEC LR6, 1.5V
(Alkaline)
Measurements Base Station (L x W x H):…………. 8.54 x 1.18 x 6.29“
(217 x 30 x 160mm)
12

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für La Crosse WS-7015 wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info