149896
7
Zoom out
Zoom in
Vorherige Seite
1/114
Nächste Seite
Note on electrostatic shielding
1. Electrostatically shielded MOS workstations
Components sensitive to electrostatic discharge must be
handled at workstation with electrostatic shielding. An elec-
trostatically shielded MOS workstation is fitted with discharge
resistor which earth all conductive materials, including the
technician working there. Dielectrics are discharged by air
ionisation. The use of soldering irons and measuring equip-
ment at shielded workstation is only possible in conjunction
with isolating transformer in each of the devices used. Meas-
uring equipment chassis are also earthed with discharge re-
sistors.
2. Shielded packaging using conductive materials
To protect against electrostatic charges, electrically conduc-
tive plastics are used for packaging and transport purposes.
Conductive plastics are available in the form of transparent
protective bags, foam plastic, film sheeting or containers.
Sensitive components requiring the use of protective pack-
aging must only be packed and unpacked at shielded work-
stations.
Safety warnings/regulations
1. The repair, modification and testing of mains-operated elec-
tronic devices and their accessories must only be performed
by qualified persons.
2. It is necessary to follow the regulations and safety warnings
to VDE 0701, part 200, as well as the regulations and safety
warnings applicable in the country concerned.
3. VDE 0701, Part 2, contains regulations on the repair, modifi-
cation and testing of mains-operated electronic devices and
their accessories.
4. Before delivery, the device and the connecting leads (includ-
ing any protective earth conductor fitted) must undergo visu-
al inspection, and the insulation resistance and the equiva-
lent leakage current must be measured according to VDE
0701, part 200. The low-resistance continuity of the protec-
tive earth conductor must be verified by measurement to VDE
regulation 0701, part 1.
5. The regulations of the country concerned must also be ob-
served.
6. Only genuine parts must be used for replacing components
marked with the symbol .
Rear panel removal
Unscrew the five rear panel screws R to remove the rear panel.
Insert screw driver into recess V. Depress interlocking and at the
same time slide rear panel to the rear (fig. 1).
How to move the chassis into the service position
1. Hold and lift the rear of the chassis and gently pull the chas-
sis toward you (fig. 2).
2. Undo the cable fixtures. Turn the chassis through 90°anti-
clockwise and place the chassis behind the set (fig. 3).
3. After servicing ensure all wiring is returned to its original po-
sition and fixed.
Service position for the signal board
1. Remove the signal board from the main chassis (Basic board),
ensuring all leads are disconnected.
2. Remove the four screws (A) (fig. 4) from the plastic AV cover
and unclip the AV cover from the signal board.
3. Remove the front metal cover from the signal board (fig. 5).
Do the same for the rear metal cover (fig. 6).
4. Fit the three extension leads to the signal board making sure
that the signal board does not touch the basic board (fig. 7).
5. After servicing ensure all wiring is returned to its original po-
sition and fixed.
Note:
The extension lead wire kit is supplied as a service kit. (Part
number 291-90274.920).
Repair information for the signal board
MediaPlus
There is any error on the signal board, please proceed as de-
scribed:
- Remove the EAROM (I 1891) from the printed circuit board. The
TV is able to keep running.
- If you get a static picture, the EAROM is out of order (possible
geometry errors remain unconsidered).
- If the error is still there, it's because of another component on
the signal board.
- If you want to change the signal board at the service head office
in Kronach, insert the EAROM from the damaged signal board
into the new one. So you don't need to make the alignment and
the programming of the TV set.
Important!
Please remove the AV cover at the damaged signal board.
1 -9
Note on electrostatic shielding
1. Electrostatically shielded MOS workstations
Components sensitive to electrostatic discharge must be
handled at workstation with electrostatic shielding. An elec-
trostatically shielded MOS workstation is fitted with discharge
resistor which earth all conductive materials, including the
technician working there. Dielectrics are discharged by air
ionisation. The use of soldering irons and measuring equip-
ment at shielded workstation is only possible in conjunction
with isolating transformer in each of the devices used. Meas-
uring equipment chassis are also earthed with discharge re-
sistors.
2. Shielded packaging using conductive materials
To protect against electrostatic charges, electrically conduc-
tive plastics are used for packaging and transport purposes.
Conductive plastics are available in the form of transparent
protective bags, foam plastic, film sheeting or containers.
Sensitive components requiring the use of protective pack-
aging must only be packed and unpacked at shielded work-
stations.
Safety warnings/regulations
1. The repair, modification and testing of mains-operated elec-
tronic devices and their accessories must only be performed
by qualified persons.
2. It is necessary to follow the regulations and safety warnings
to VDE 0701, part 200, as well as the regulations and safety
warnings applicable in the country concerned.
3. VDE 0701, Part 2, contains regulations on the repair, modifi-
cation and testing of mains-operated electronic devices and
their accessories.
4. Before delivery, the device and the connecting leads (includ-
ing any protective earth conductor fitted) must undergo visu-
al inspection, and the insulation resistance and the equiva-
lent leakage current must be measured according to VDE
0701, part 200. The low-resistance continuity of the protec-
tive earth conductor must be verified by measurement to VDE
regulation 0701, part 1.
5. The regulations of the country concerned must also be ob-
served.
6. Only genuine parts must be used for replacing components
marked with the symbol .
Rear panel removal
Unscrew the five rear panel screws R to remove the rear panel.
Insert screw driver into recess V. Depress interlocking and at the
same time slide rear panel to the rear (fig. 1).
How to move the chassis into the service position
1. Hold and lift the rear of the chassis and gently pull the chas-
sis toward you (fig. 2).
2. Undo the cable fixtures. Turn the chassis through 90°anti-
clockwise and place the chassis behind the set (fig. 3).
3. After servicing ensure all wiring is returned to its original po-
sition and fixed.
Service position for the signal board
1. Remove the signal board from the main chassis (Basic board),
ensuring all leads are disconnected.
2. Remove the four screws (A) (fig. 4) from the plastic AV cover
and unclip the AV cover from the signal board.
3. Remove the front metal cover from the signal board (fig. 5).
Do the same for the rear metal cover (fig. 6).
4. Fit the three extension leads to the signal board making sure
that the signal board does not touch the basic board (fig. 7).
5. After servicing ensure all wiring is returned to its original po-
sition and fixed.
Note:
The extension lead wire kit is supplied as a service kit. (Part
number 291-90274.920).
Repair information for the signal board
MediaPlus
There is any error on the signal board, please proceed as de-
scribed:
- Remove the EAROM (I 1891) from the printed circuit board. The
TV is able to keep running.
- If you get a static picture, the EAROM is out of order (possible
geometry errors remain unconsidered).
- If the error is still there, it's because of another component on
the signal board.
- If you want to change the signal board at the service head office
in Kronach, insert the EAROM from the damaged signal board
into the new one. So you don't need to make the alignment and
the programming of the TV set.
Important!
Please remove the AV cover at the damaged signal board.
1 -9
7

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln
1

Forum

loewe-1670-z-contur

Suche zurücksetzen

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Loewe 1670 z contur wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info