EnglishDeutsch Page 37
Attention:
Before opening the housing, always disconnect the
operator from the mains!
Remove the motor cover's central fixing screw (A).
Press all four locking hooks (B) inwards and pull the motor cover down and off.
Slide belt cover (C) approx. 5 mm in the direction of the arrow,
press together at the bottom and pull away upwards.
Slip the drive belt first over the small lower motor pulley (D) and
then over the large upper spindle pulley (E).
Do not use any sharp-edged tools.
Re-assemble in reverse sequence.
Altering the door travel speed for large doors and for retractable
up-and-over doors.
Only to be carried out by a specialist!
The operator is supplied set for the faster door travel speed of approx. 14 cm/s.
By relocating the drive belt, the door travel speed can be reduced to approx. 8 cm/s.
O
11
O
12
Screw in the light bulb (max. 40 Watt, E 14) and push retention ribs (A) on the lamp cover
underneath the two locating slots (B) on the motor housing.
Swivel the lamp cover downwards and screw in place as shown.
After an impulse has been given, the light stays on for approx. 3 mins.
Light bulbs are not covered by the guarantee.
Attention:
In the disengaged state, the door may only be
moved with moderate speed.
In order to prevent the carriage from colliding with the operator housing on
manual operation of the door, the travel path of the door in the OPEN direction
must be limited on site.
Quick release:
Pull cord (A) to disengage the door from the electric operator.
When an impulse is given whilst the door is released, the carriage will automatically re-engage.
To permanently disengage the door from the operator, push lever (B) fully forward.
O
13
Seite 28
90 sek.
95 sek.
100 sek.
110 sek.
120 sek.
130 sek.
140 sek.
150 sek.
160 sek.
170 sek.
180 sek.
190 sek.
200 sek.
210 sek.
220 sek.
240 sek.
deaktiviert
1 sek.
2 sek.
3 sek.
4 sek.
5 sek.
6 sek.
7 sek.
-
-
-
-
-
-
-
-
deaktiviert
2 sek.
5 sek.
10 sek.
15 sek.
20 sek.
25 sek.
30 sek.
35 sek.
40 sek.
45 sek.
50 sek.
55 sek.
60 sek.
65 sek.
70 sek.
deaktiviert
5 sek.
10 sek.
15 sek.
20 sek.
25 sek.
30 sek.
35 sek.
40 sek.
50 sek.
80 sek.
100 sek.
120 sek.
150 sek.
180 sek.
255 sek.
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
LED Anzeige
Menü 1:
Torauf
Ebene 3: Automatischer Zulauf
Ebene 5: Antriebsbeleuchtung/
Signalleuchten
Menü 2:
Vorwarnzeit
Menü 3:
Anfahrwarnung
Menü 1:
Beleuchtungszeit
Deaktivierung Automatischer Zulauf (beide Zeiten ohne Funktion)
Wird gemäß Tabelle die Aufzeit oder Vorwarnzeit 'deaktiviert' eingestellt, ist der 'Automatische Zulauf' ausgeschaltet.
= Werkseinstellung
Programmiertabelle Comfort 150/160 DC
O
23