481388
9
Zoom out
Zoom in
Vorherige Seite
1/16
Nächste Seite
ON/OFF
CLOCK
RESET
HR.
MIN.
COOL/ HEAT / DRY mode operation procedure
With the remote controller pointing towards the air conditioner.With the remote controller pointing towards the air conditioner.
Press the ON/OFF button.
1
3
Press the MODE select button.
Move the MODE to the desirable operation position.Move the MODE to the desirable operation position.
[ (COOL), (HEAT), (DRY) (AUTO) (FAN) ][ (COOL), (HEAT), (DRY) (AUTO) (FAN) ]
2
4
Set to your favorite temperature press or button.
Standard.
Set to your favorite temperature press or button.
Standard.
Press the TEMP . button.
If FAN is selected, room temperature isn't controlled,operation being continuously.If FAN is selected, room temperature isn't controlled,operation being continuously.
26 C ~28 C
HEAT
22 C ~24 C
COOL
DRY
21 C ~24 C
NOTE
Press the FAN SPEED button.
Set to your favorite air flow rate.Set to your favorite air flow rate.
To Stop:
Press the ON/OFF button.
Air is not blown out at during operation.Air is not blown out at during operation.
Changing procedure of the content of the operation
Set to the new content.Set to the new content.
The content of the operation can be set or changed
even while the air conditioner is off operation.
The content of the operation can be set or changed
even while the air conditioner is off operation.
2
1
4
3
When cells are inserted,the present time is automatically set to AM12:00When cells are inserted,the present time is automatically set to AM12:00
Ex:Set to AM10:30.Ex:Set to AM10:30.
1
Please slide and remove the cover.
Press the CLOCK switch,with the tip of a ball pen, etc,
the present time can be set.
3
NOTE
The timer is set on the basis of the present time.So set the
present time correctly.
The timer is set on the basis of the present time.So set the
present time correctly.
1,4
2
Press the HR button to set the HR .
Press the HR button to set the MIN .
Press the clock switch to confirm.
ON/OFF
CLOCK
RESET
HR.
MIN.
Present time setting procedure
7
Specification of
Liquid pipe
12.7
9.52
6.35
Max. length
20m
15m
25m
Additional refrigerant
(L-5)X0.05 kg
(L-5)X0.03 kg
(L-5)X0.10 kg
The additional refrigerant should be charged from the service port of the 3-way valve
when the appliance is operating in cooling mode.
Do not allow air enter the refrigeration system while charging refrigerant.
(* "L" refers to length of connection pipe.)
Open/Close the valves
Open/Close the spools or the valves of outdoor unit with a f5mm hexagon spanner.
!
WARNING
Specified power cables should be used. Do not apply any pressure on the
terminals used to connect.
Grounding must be properly done.
Improper connection may cause fire.
Electric Wiring must be done by professionals. Use a separate circuit according
to national regulations.
The grounding wire should be away from gas pipes, water pipes, telephone,
lightening rods or other grounding wires. Improper grounding may cause electric
shock.
If the wiring capacity is not enough, electric shock or fire may occur.
If the supply cord is damaged, it must be replaced by the manufacturer or its service agent
or a similarly qualified person in order to avoid a hazard
An all-pole disconnection switch having a contact separation of at least 3mm in all poles sho-
uld beconnected in fixed wiring.
Be sure to Install Current Leakage Protection Switch. Or electric shock may occur.
the appliance must be positioned so that the plug is accessible
the appliance shall be installed in accordance with national wiring regulations
CAUTION
22
ELECTRIC WIRING
The temperature of refrigerant circuit will be hight ,please keep the interconnection
able away from the copper tube.
3
4
2
3
9

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Maxicool CTL50H4A wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info