7-MAINTENANCE AND CLEANING
CLEANING THE SMOKE DUCT AND FITTING
When the product is extracted, you can intervene on the smoke fan (1) from the left side for cleaning and maintenance purposes. Clearly,
the smoke evacuation fan must be removed for such maintenance to be performed.
A gasket (3) is applied on the fan outlet, which guarantees the tightness with the smoke tting (2). Always verify that this gasket is
intact and if necessary, replace it. The gasket can also be adjusted via a screw. The pressure on the tting can be increased or decreased
by loosening the screw.
The ue connection to its ash collection compartment (4) is located in the rear/lateral part of the product, in line with the fan outlet. Also
clean this compartment with a vacuum cleaner by inserting the nozzle on the fan inlet hole. Then clean the smoke exhaust, especially
around the ttings, curves and any horizontal sections. For information on cleaning the ue, contact a chimney sweeper.
ATTENTION: The frequency with which the smoke exhaust must be cleaned depends on the use of the product
and the type of installation.
OTHER CHECKS
All the tightness gaskets tted on the components on which maintenance is to be performed (smoke evacuation fan, inspection sections,
etc.) must be replaced when these are removed for maintenance purposes. Verify the tightness of the gaskets on the hearth door and if
necessary, contact an authorized service centre for them to be replaced.
The company recommends contacting an authorised service centre for end-of-season maintenance and cleaning as the above-mentioned
operations will be performed together with a general inspection of the components.