58
17-ALARMS
Mechanical stove block
The following conditions may cause the mechanical stove block:
• Structure overheating (“A03”)
• Smoke overheating (“A04”)
• During stove operation air has entered the combustion chamber or there is an obstruction in the ue (“A05”)
The block is signalled on the display and with a sound signal. In this situation the shutdown stage is activated automatically.When this
procedure is started, any test operation to restore the system is useless. The display signals the cause of the blockage.
SOLUTIONS:
If “A03” appears: the structure is too hot because the product has been used for too long at the maximum power or there is poor ventilation.
When the product is suciently cold, press button B on the control panel or OFF on the remote control to cancel alarm A03. Once the
alarm is cancelled, the product can be switched on normally.
If “A04” appears: The stove switches o automatically. Let the stove cool down for a few minutes and then switch it on again. Check the
smoke expulsion and verify the type of pellet used according to the instructions found in Chap. 2 of this manual.
If “A05” appears: the door has been left open for too long or a signicant amount of air has entered (e.g. missing smoke fan inspection
cap). If these causes are excluded, check and if necessary clean the smoke duct and ue. (it is recommended that this operation is carried
out by an MCZ qualied technician.
The product can be switched on again only after having eliminated the cause permanently.