Chapter 6
INSTALLATION AND USE MANUAL
page 36
Operation Technical service – MCZ Group S.p.A. all rights reserved - Reproduction prohibited
6.4. FIRST LIGHTING
It is advisable to approach the first lighting with caution, using
good-quality, well-seasoned wood.
The primary air inlet must be fully open. Do not use alcohol,
petrol, or other volatile flammable substances. On first lighting,
fumes and unpleasant smells may be given off, caused by the drying of
the product; this is not hazardous to the health, and it is sufficient to
ventilate the room adequately. Once combustion has started, pieces of
wood of normal size may be added.
The flame must have as far as possible a smooth and laminar flow. On
the various occasions when the stove needs reloading, the
door should be opened slowly, to avoid blowbacks of smoke
into the room.
Proceed as follows:
Place a small amount of balled paper in the stove.
Cover the paper with a small quantity of twigs and a few pieces of
wood.
Open the primary air register completely (turn completely to the
left) fig.14
Light the paper and if necessary leave the door open to the first
stage.
When the twigs are burning, the door can be closed.
Only once the flame is burning well (presence of a bed of coals and
full combustion), place the air adjustment between the two flames
(see fig.14) large flame to obtain nominal power, small flame for
slow combustion.
As the fire burns, add wood. Never overload the fireplace stove
with wood (see technical specifications in the table).
As soon as the flames have died down and a bed of embers has
formed, load the stove normally. Small loads of wood are preferable to
large ones for combustion.
Attention
Do not use volatile, flammable substances
(petrol, alcohol etc.) for lighting the fire.
Do not use fuels which could release toxic
substances or pollutants.
Do not put the fire out by throwing water on it.
Check the external and internal air intakes, and
the flue pipe, at least once a year, arranging for
them to be cleaned.
During use, the metal parts and the glass reach
high temperatures. For all jobs of loading the
stove, adjustment or cleaning the ash drawer,
use the insulating glove provided.
Never leave children unattended near the
fireplace stove when it is in use.
The risk of burns from contact with hot surfaces
is very high.
Figure 15 - Door open to first stage
Figure 14 - Adjustment of air register
36

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für MCZ Vivo 70 Wood wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info