600820
8
Zoom out
Zoom in
Vorherige Seite
1/52
Nächste Seite
ENGLISHen
8
When using universal swivel cou-
plings (bayonet couplings), only
use versions with an additional
securing ring to ensure safe seal-
ing.
See page 2. The illustrations serve as examples
for all devices.
1 Water drain screw
2 Pressure switch *
3 Pressure gauge (water pressure) *
4 Suction connection
5 Water filling screw
6 Pressure connection
7Pump
8 On/off switch
9 Air valve for pilot pressure *
10 Pressure vessel *
* depending on model
6.1 Setting pilot pressure
Set the pilot pressure before initial operation. See
section 9.4.
6.2 Installation
The device must be positioned on a horizontal, flat
surface that is suitable for the device weight with
water filling.
To avoid vibrations, the device should not be
bolted on but rather should be positioned on a
resilient base.
The place of installation should be well ventilated
and protect against weather influences. Protect
against frost - see section 8.2.
For operation in garden ponds and
swimming pools, the device must
be installed in a flood-proof loca-
tion and secured against falling in.
Additional statutory requirements
must be taken into consideration.
6.3 Connecting suction line
Caution! The suction line must be installed
such that no mechanical or twisting forces
are exerted on the pump.
Caution! Use an intake filter to protect the
pump against sand and contamination.
Caution! The check valve is absolutely
necessary to prevent the water from draining
when the pump is switched off. We recommend
the installation of check valves at the intake
opening of the suction hose and at the suction
connection (4) of the pump. Depending on the
model, a check valve may already be integrated
(see section 13. Technical Specifications).
Seal all screw-coupling with thread sealing tape.
Leaks result in air intake and reduce or prevent the
water intake.
The suction line should have an inside diameter of
at least 1" (25 mm); it must be kink- and vacuum-
resistant.
The suction line should be as short as possible
because the longer the line length, the lower the
conveying capacity.
The suction line should rise uniformly towards the
pump to prevent air inclusions.
A sufficient water supply must be guaranteed and
the end of the suction line should always be under
water.
6.4 Connecting the discharge line
Caution! The discharge line must be installed
such that no mechanical or twisting forces
are exerted on the pump.
Seal all screw-couplings with thread sealing tape
to prevent water discharge.
All components of the discharge line must be pres-
sure-resistant and installed correctly.
Danger! If non-pressure-resistant compo-
nents are installed, or assembly is incorrect,
the discharge line can burst during operation. Inju-
ries are possible if highly pressurised fluids are
ejected!
6.5 Connection to a pipe network
To reduce vibration and noises, the device should
be connected with flexible hose lines to the pipe
network.
6.6 Mains connection
Danger! Risk of electric shock!
Never operate the device in a
wet environment and only under
the following conditions:
- Connect only to an earthed outlet
that is properly installed, earthed
and tested.
- Mains voltage, mains frequency
and fuse protection must corre-
spond to those stated in the
'Technical Specifications'.
- The device must be supplied via
a residual-current device (RCD)
with a rated residual current of
max. 30 mA.
- The electrical connections must
not be under water and must be
located in a flood-proof area. The
connections must be splash-
proof for outdoor use.
- Extension cables must have
sufficient conductor cross
sections. Unroll cable reels fully.
- National installation specifica-
tions must be observed.
6.7 Filling pump and suction
Caution! In the case of a new connection,
water loss or air intake, the pump must be
filled with water. Operation of the pump without
water filling will destroy it!
- Unscrew water filling screw (5) including gasket.
- Slowly pour in clean water until the pump is filled.
- Screw in water filling screw (5) with gasket again.
- Open the discharge line (open water tap or spray
nozzle) so that air can escape during suction.
- Switch on the device (see section 7.).
- When water emerges evenly, the device is ready
for operation.
Note:
The suction line does not need to be filled
because the pump is self-priming. Depending on
the length and diameter of the line, however, it may
take some time until pressure is built up. To
shorten the suction time: install a check valve at
the intake opening of the suction hose and fill the
suction line too.
Caution! The pump and suction line must be
connected and filled (see section 6.).
Caution! The pump must not be allowed to
run dry. There must always be sufficient
conveying medium (water) available.
If the pump is blocked by foreign bodies or the
motor is overheated, a protective circuit shuts
down the motor.
7.1 Using the device
Pump
(device designation P...)
Functional principle: the device runs as long as the
on/off switch (8) is activated.
Danger! If the discharge line is closed, run the
pump for a maximum of 5 minutes because
otherwise overheating of the water in the pump can
cause damage.
1. Insert mains plug.
2. Turn on at switch (8).
3. Open the discharge line (open water tap or
spray nozzle).
4. Check that water emerges!
5. When work is complete, turn off the device at
the switch (8).
Domestic water system
(device designation HWW...)
Functional principle: the device switches on when
the removal of water causes the water pressure to
fall below the switch-on pressure; it switches off
again when switch-off pressure is reached. The
pressure vessel contains a rubber bellows, which
is under air pressure (pilot pressure) when deliv-
ered; this permits the removal of small volumes of
water without the pump starting up.
1. Insert mains plug.
2. Turn on at switch (8).
3. Open the discharge line (open water tap or
spray nozzle).
4. Check that water emerges!
Danger! Prior to all servicing:
- Unplug mains cable.
- Ensure that the device and connected accesso-
ries are depressurised.
- Repair and maintenance work other than
described in this section should only be carried
out by qualified specialists.
8.1 Regular maintenance
- Check device and accessories, in particular,
electrical and pressurised components, for
damage and repair if necessary.
- Check suction and discharge lines for leaks.
- If the conveying capacity decreases, clean intake
filter and filter element (if installed) and replace if
necessary.
- Check the pilot pressure of the pressure vessel
(10) (depending on features) and increase it if
necessary (see section 9.4 Increasing pilot pres-
sure).
8.2 Danger of frost
Caution! Frost (< 4 °C) destroys the pump
and accessories as both always contain
water!
- If there is a danger of frost, disassemble pump
and accessories and store in frost-free condi-
tions (see following section).
8.3 Removing and storing device
- Turn off at switch (8). Unplug mains cable.
- Open the discharge line (open water tap or spray
nozzle), allow water to drain off completely.
- Completely drain the pump (7) and vessel (10)
by:
- unscrewing the water drain screw (1).
- Remove suction and discharge lines from
device.
- Store device in a frost-free room (min. 5 °C).
f
Danger!
- Prior to all servicing:
- Unplug mains cable.
- Ensure that the device and connected accesso-
ries are depressurised.
9.1 Pump is not running
No mains voltage.
- Check on/off switch, cables, plug, socket and
mains fuse.
Mains voltage too low.
- Use an extension cable with sufficient
conductor diameter.
Motor overheated; motor protection relay
tripped.
- After cooling the pump will switch on again.
- Guarantee sufficient ventilation, keep air slots
free.
- Observe maximum supply temperature.
Motor hums, but does not start.
- With the motor switched off, insert a screw-
driver or similar object through the air slots on
the motor and turn the fan impeller.
5. Overview
6. Initial Operation
7. Operation
8. Maintenance
9. Troubleshooting
8

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln
1

Forum

metabo-hww-9000-100-g

Suche zurücksetzen

  • wie kann man den druckschalter bei der hww 9000-100 g einstellen bitte anleitung Eingereicht am 16-11-2023 20:03

    Antworten Frage melden
  • metabo hauswasserwerk hww 9000/100g
    druckschalter einstellen , das gerät springt nicht an, kann ich am druckregler einstellen ?es sind ja 2 stellschrauben. einmal metall und einmal plaste schraube ?! Eingereicht am 14-6-2023 15:02

    Antworten Frage melden
  • Hallöchen, ich kann den Vorfülldruck nicht einregeln. Es ist nicht möglich Druck aufzubauen, bzw auch nur überhaupt etwas Luft in den Kessel zu bekommen. Weder mit Luftpumpe, noch mit Kompressor. Woran kann es liegen, Druck und Wasser ist abgelassen. Eingereicht am 1-11-2022 13:09

    Antworten Frage melden
  • Metabo 9000.
    Schaltet erst bei einen Druck unter 2bar ein.
    Habe kein Wasser in den Versenkrehnern Eingereicht am 25-7-2022 19:21

    Antworten Frage melden
  • hallo in der Runde, meine Pumpe läuft an und schaltet bei einem Verbraucher ein...Druckverlust...ein
    habe ich 6 Sprenger an, läuft sie durch. ich glaube der druckregler muß neu eingestellt werden...
    Metabo HWW 9000/100G mit Kessel...Was kann ich tun, wie wird die Pumpe neu eingestelt... Eingereicht am 14-7-2022 19:42

    Antworten Frage melden
  • Mein HWW 4000/25 gibt keinen Ton von sich. Der Druckschalter zeigt, dass Strom anliegt, der Motor bleibt stumm. Gerade noch gelaufen, plötzlich keine Reaktion mehr. Was kann ich als Laie tun? Gibt es eine Sicherung, die man wechseln könnte? Eingereicht am 30-4-2022 09:42

    Antworten Frage melden
  • metabo hauswasserwerk hww 9000/100g
    druckschalter einstellen Eingereicht am 20-8-2021 20:53

    Antworten Frage melden
  • Strom vorhanden, Pumpe läuft nicht, Druckschalter schaltet nicht von allein. Eingereicht am 15-5-2021 17:32

    Antworten Frage melden
  • Pumpe befüllt Wasserbehälter zu schnell jede Sekunde versucht sie zu Pumpen Eingereicht am 9-8-2020 09:30

    Antworten Frage melden
  • Kann man den abschaltdruck von 3,9 auf 5bar erhöhen Eingereicht am 7-7-2020 18:56

    Antworten Frage melden
  • Wie stellt man den Einschaltdruck bei der Pumpe HWW9000/100G ein Eingereicht am 19-5-2019 09:14

    Antworten Frage melden
  • Strom vorhanden, Pumpe läuft nicht, Druckschalter schaltet nicht von allein, wird er von Hand gedrückt
    läuft sie. Eingereicht am 3-4-2018 13:44

    Antworten Frage melden
  • Lautes geräusch wenn sie sich einschaltet Eingereicht am 3-1-2017 19:49

    Antworten Frage melden

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Metabo HWW 9000-100 G wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info