600618
13
Zoom out
Zoom in
Vorherige Seite
1/92
Nächste Seite
ENGLISH en
13
6.3 Dust extraction
Always use a suitable dust extraction system:
Connect an M-class vacuum cleaner to the
extractor connection piece (1).
Disconnect the mains plug before changing
any accessories. The machine must be
switched off and the spindle must be at a standstill.
7.1 Locking the spindle
Press in the spindle locking knob (9) only
when the spindle is stationary!
- Press in the spindle locking button (9) and turn the
spindle (8) by hand until you feel the spindle
locking button engage.
7.2 Fitting/removing the routing tool
For safety reasons, use the safety guard (19)
with the attached depth stop (22).
See illustration B on page 2.
To fit:
- Lock the spindle (see chapter 7.1).
- Screw on and tighten the routing tool (7) using the
2-hole spanner (6) in a clockwise direction.
To remove:
- Lock the spindle (see chapter 7.1). Unscrew the
routing tool (7) with the 2-hole spanner (6) in an
anticlockwise direction.
7.3 Fitting/removing the diamond cup wheel
For safety reasons, use the safety guard (19)
with the attached depth stop (22).
See illustration C on page 2.
To fit:
- Fit the support flange (12) on the spindle. (8) The
flange should not turn on the spindle when
properly attached.
- Lay the diamond cup wheel (11) on the support
flange (12) so that it lies flat along the support
flange.
- The 2 sides of the clamping nut (10) are different.
Screw the clamping nut onto the spindle so that
the band of the clamping nut (10) is facing upward.
- Lock the spindle (see chapter 7.1). Turn the
clamping nut (10) clockwise using the 2-hole
spanner (6) to secure.
To remove:
- Lock the spindle (see chapter 7.1). Turn the
clamping nut (10) anticlockwise using the 2-hole
spanner (6) to unscrew.
8.1 Setting speed
Set the optimum speed on the setting wheel (18),
depending on the application.
8.2 Switching On and Off
Always guide the machine with both hands.
Switch on first, then guide the
accessory
towards the workpiece.
The machine must not be allowed to draw in
additional dust and shavings. When switching
the machine on and off, keep it away from dust
deposits. After switching off the machine, only place
it down when the motor has come to a standstill.
Avoid inadvertent starts: always switch the
tool off when the plug is removed from the
mains socket or if there has been a power cut.
In continuous operation, the machine
continues running if it is forced out of your
hands. Therefore, always hold the machine with
both hands using the handles provided, stand in a
safe position and concentrate.
Machines with slide switch:
Switching on: Push the slide switch (15) forward.
For continuous activation, now tilt
downwards until it engages.
Switching off: Press the rear end of the slide
switch (15) and release.
Replace worn or damaged routing wheels (see
figure, page 2):
- Removing the routing tool (see chapter 7.2).
- Extract the screw (13) in an anticlockwise
direction. Remove the safety disc (14).
- Replace all routing wheels as shown.
(Always use the same type of routing wheels).
-Reassemble all parts as shown.
Insert and turn the screw (13) in a clockwise
direction and tighten with 7 Nm ± 1 Nm.
Motor cleaning: blow compressed air through the
rear ventilation slots of the machine regularly,
frequently and thoroughly. The machine must be
held firmly in this case.
The electronic signal display (17) lights
up and the load speed decreases. The coil
temperature is too high! Run the machine in
idling until the electronics signal indicator switches
off.
The electronic signal display (17) flashes
and the machine does not start. The restart
protection is active. If the mains plug is
inserted with the machine switched on, or if the
current supply is restored following an interruption,
the machine does not start up. Switch the machine
off and on again.
7. Attaching the accessory
8. Use
9. Maintenance
10. Cleaning
11. Troubleshooting
0
I
15
13

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Metabo RF 14-115 wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info