For allowable temperature setting ranges, refer to the range setting of set temp.
Reference set temp
  Cooling 26 to 28°C Dry 24 to 26°C Heating 20 to 24°C Fan Setting temp is not required.
If the Auto is selected for the set temp, the set temp display shows 0. Temperature can be adjusted higher or lower with using buttons. Note that Auto is not displayed and
cannot be set when SC-SL2, SC-SL3, or SC-SL4 is connected.
If the Back button is tapped without tapping the Set button, the selected set temp is invalidated and the display returns to the TOP screen.
Change flap direction
Menu
Direction
Cooling
1614
(Mon)
F1: High power
Timer
Now stopping.
Set temp
F2: Energy-saving
Change flap direction
Ind. flap
Control
Back
4
Tap the desired ap direction. After
selecting the ap direction, the display
returns to the Select ap screen. (
1)
5
When the 3D auto ow operation is
enabled, “3D AUTO” is displayed on
the Change flap direction button, as
shown on the left.
Menu
Direction
Auto
1614
(Mon)
F1: High power
Timer
Now stopping.
Set temp
MEETING1
Room
3D AUTO
F2: Energy-saving
Select flap
Upper/lower flap
Back
Select the flap to change.
Left/right flap
3D AUTO 2
1
R/C Room
Outdoor
3
When multiple IUs are connected to the remote control for a mixed environment consisting of FDKs with a left/right flap and IUs without a left/right flap, enabling the 3D auto flow operation will set the
models without a left/right flap to a flap position set before the 3D auto flow operation was started.
Since the flap is controlled automatically in the following operation, it may differ from the display on the R/C.
  When the room temperature is higher than the set temp (In case of the heating operation)
  When the In operation for heating standby. or In operation for defrosting. is displayed (In case of the heating operation).
  Cool air is blown horizontally not to blow directly to human body.
  In a high humidity environment (during cooling operation)
When you select Auto swing while the Anti draft setting is enabled, the flap will not swing and be set at flap position 1.
Changing the left/right flap direction and 3D auto flow operation cannot be performed from the SC-SL2, SC-SL3, or SC-SL4. Also note that 3D auto flow operation will not be disabled when you
change the flap direction from the SC-SL2, SC-SL3, or SC-SL4 during a 3D auto flow operation.
1 Tap the Change flap direction button on the TOP screen.
When an FDK with a left/right ap is not connected: 2
When one or more FDKs with a left/right ap are connected: 3
Change flap direction
Ind. flap
Control
Auto swing
Back
OutdoorRoomR/C
Select the flap direction.
2
When the Change ap direction screen is displayed, tap the button of desired ap direction.
To swing the ap, tap the Auto swing button.
To x the ap position, tap one of 1 to 4 buttons.
After selecting the ap direction,
When an FDK with a left/ right ap is not connected, the display returns to the TOP screen. (1)
When an FDK with a left/right ap is connected, the display returns to the Select ap screen. (3)
3
When one or more FDKs with a left/right ap are connected, the Select ap screen is displayed. Select the desired ap direction.
To change the up/down ap direction, tap the
Upper/lower flap
button. The Change ap direction screen for the up/down
ap is displayed. (2)
To change the left/right ap direction, tap the
Left/right flap
button. The Change ap direction screen for the left/right ap is
displayed. (4)
The 3D auto ow operation automatically controls the fan speed and ap direction to efciently condition the air of the entire
room.
To switch to the 3D auto ow operation, tap 3D AUTO to enable the operation.
To disable the 3D auto ow operation, tap the 3D AUTO again. The ap direction returns to the direction that was set before
the 3D auto ow operation was enabled. The 3D auto ow operation will also be disabled when you change the up/down or left/
right ap direction during the 3D auto ow operation.
Note
Do not manually move the flaps or panel with anti draft by force. It could damage these flaps and panels.
Do not blow air downward for a long period of time during the cooling operation. Condensation may be generated and water may drip from the side panel. (In case of Ceiling suspended type)
For FDKs with a left/right flap, it is recommended that the flap should be set toward the right side when there is a wall on the left, or set toward the left side when there is a wall on the right. For more
information, refer to the Notes in the Individual flap control section.
28

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Mitsubishi RC-EX3 - REMOTE CONTROL wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Andere Handbücher von Mitsubishi RC-EX3 - REMOTE CONTROL

Mitsubishi RC-EX3 - REMOTE CONTROL Bedienungsanleitung - Deutsch - 46 seiten

Mitsubishi RC-EX3 - REMOTE CONTROL Kurzanleitung - Holländisch - 46 seiten

Mitsubishi RC-EX3 - REMOTE CONTROL Kurzanleitung - Französisch - 46 seiten


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info