8
4.9 ENTRY INDICATION
No entry indication is set a the factory default. It is possible to hear an
indication beep during the entry delay. This can be used as a reminder that
the Mobeye is in active mode. It is also possible to let the LED indicator
flash a few times, as an indicator for the user.
4.10 SIREN
After the entry delay, the siren can sound for two minutes. At the same time
the SMS text messages and telephone calls will be sent. At soon as the
Mobeye is switched off, the siren will stop. The siren is set to silent as the
factory default.
4.11 EXIT INDICATION
Upon arming the system, you have one minute to leave the room. The PIR
is not active yet and an exit indication sounds. It is possible to change this
to a silent exit time. A short beep is heard and the LED flashes red during
the exit time.
4.12 TEMPERATURE ALARM
The Mobeye i110 is able to send a temperature alarm as soon as the actual
temperature reaches a programmed min. or max. level. This function can
be used independently of the motion detection. As soon as the temperature
is too high or too low, an SMS text message is sent, followed by a
telephone call. As long as the out of range temperature remains, the report
will be repeated hourly. Once the temperature is back to normal, the
Mobeye i110 confirms this to you.
This function is active as soon as a temperature limit is programmed. By
resetting the limits, the function becomes inactive.
4.13 ADJUSTING THE TEMPERATURE
The built-in temperature sensor may have a standard deviation of the actual
temperature. In this case, the deviation will be similar at all temperatures. It
is possible to correct the temperature deviation in the Mobeye i110. In the
SMS setting summary, you see the reported temperature. If a correction is
specified, it is processed in the displayed temperature; the correction factor
itself is displayed separately.
Example: Mobeye temperature: 13 C. Actual temperature: 14 C. To
correct this deviation, one degree should be added.