9
4.14 INTERVAL TEST MESSAGE
The Mobeye i110 can send test messages. Through these test reports you
will be informed of the status of your system. The interval between test
reports is adjustable between 0 (no test reported) and 30 (once every 30
days). Note: the interval of 1 day will result in a daily test message; the
exact time between the messages will be about 24 hours.
The smaller the interval between the test reports, the shorter is the battery
life. The test message only works if the system is on or a temperature limit
is set.
4.15 SETTING THE CURRENT TIME AND DATE
Some telecom providers offer this in the network, which is updated by the
Mobeye i110 during the start-up and after sending test messages. It is
possible to set the time and date manually. To view the clock time, send a
list of the settings to the first phone number (CODE MENU 10 OK).
4.16 USER CODE
The Mobeye i110 offers the possibility to set a personal 4-digit user code,
for just arming and disarming the system. It is not possible to change the
settings with the user code. The system needs to be switched on and off
using the same code; the installation code and user code are not
interchangeable. Factory settings for the user code is “8888”. This code can
be changed by the installation code or user code (menu number 50). We
recommend you to change this code to make the unit more secure.