25
GB
for camera remote control:
for focus setting (far)
15 Button PLAY/STOP to start and stop the replay
for camera remote control:
to close the iris
16 Button MODE to switch between various split-
screen arrangements (4, 9, 16 camera images)
on the main monitor
for camera remote control:
to open the iris
when defining the coverage for automatic motion
detection:
to activate / deactivate all grid fields
17 Button SEARCH to search for particular record-
ings according to recording time or event
for camera remote control:
to zoom out
with the on-screen keyboard inserted:
for quick input of the word “user”
18 Button MENU to activate the OSD menu
for camera remote control:
to zoom in
with the on-screen keyboard inserted:
for quick input of the word “admin”
1.2 Rear side of recorder
19 Jack LAN to connect a computer network (Ether-
net) for remote control via a computer
20 Jack VGA to connect a computer monitor with
VGA input
21 BNC jack VIDEO OUT or MAIN MONITOR to
connect the (main) monitor
22 Video inputs as BNC jacks to connect the cam-
eras
(CH 9 – CH 16 for DMR-616 only)
23 Strain relief strap for the power supply cable to
prevent accidental disconnection
24 USB port to connect a mouse
25 Selector switch PAL / NTSC to select the video
system
26 D-Sub connection jack for the camera remote
control via RS-485 and the alarm connections
pin configuration:
DMR-604
1 alarm output: NO contact
2 alarm output: common contact
3 RS485 D+
4 RS485 D
-
5 alarm input of channel 1
6 alarm input of channel 2
7 alarm input of channel 3
8 alarm input of channel 4
9 alarm output: NC contact
10 – 15 ground
DMR-608 and DMR-616
1 alarm output: NO contact
2 alarm output: common contact
3 RS485 D+
4 RS485 D
-
5 not used
6 alarm input of channel 1
7 alarm input of channel 2
8 alarm input of channel 3
9 alarm input of channel 4
10 alarm input of channel 5
11 alarm input of channel 6
12 alarm input of channel 7
13 alarm input of channel 8
14 alarm output: NC contact
15 – 17 not used
18 alarm input of channel 9
(DMR-616 only)
19 alarm input of channel 10
(DMR-616 only)
20 alarm input of channel 11
(DMR-616 only)
21 alarm input of channel 12
(DMR-616 only)
22 alarm input of channel 13
(DMR-616 only)
23 alarm input of channel 14
(DMR-616 only)
24 alarm input of channel 15
(DMR-616 only)
25 alarm input of channel 16
(DMR-616 only)
27 RCA jack AUDIO OUT or MAIN AUDIO for con-
nection to the audio input of the (main) monitor
28 Audio inputs for the audio signals of the cameras
as RCA jacks (DMR-604) or D-Sub jack (DMR-
608 and DMR-616, an adapter for RCA inline
jacks is supplied)
pin configuration of the D-Sub jack
(DMR-608 and DMR-616 only):
1 audio input of channel 1
2 audio input of channel 3
3 audio input of channel 5
4 audio input of channel 7
5 audio input of channel 9
(DMR-616 only)
6 audio input of channel 11
(DMR-616 only)
7 audio input of channel 13
(DMR-616 only)
8 audio input of channel 15
(DMR-616 only)
9 – 12 ground
13 not used
14 audio input of channel 2
15 audio input of channel 4
16 audio input of channel 6
17 audio input of channel 8
18 audio input of channel 10
(DMR-616 only)
19 audio input of channel 12
(DMR-616 only)
20 audio input of channel 14
(DMR-616 only)
21 audio input of channel 16
(DMR-616 only)
22 – 24 ground
25 not used
29 Jack DC 12 V / 5 A for power supply via the
power supply unit provided and connected to
100 – 240 V~ / 50 – 60 Hz
DMR-608 and DMR-616 only:
30 RCA jack CALL AUDIO for connection to the
audio input of an additional monitor
31 BNC jack CALL MONITOR for connection to the
video input of an additional monitor
2 Safety Notes
The units (video recorder and power supply unit)
correspond to all required directives of the EU and
are therefore marked with .
Please observe the following items in any case:
G
The units are suitable for indoor use only. Protect
them against dripping water and splash water,
high air humidity and heat (admissible ambient
temperature range 0 – 40 °C).
G
Do not place any vessel filled with liquid on the
units, e. g. a drinking glass.
G
The heat generated within the video recorder must
be dissipated by air circulation. Therefore, do not
cover the air vents of the housing.
G
Do not operate the units and immediately discon-
nect the mains plug of the power supply unit from
the socket
1. if one of the units or the mains cable is visibly
damaged,
2. if a defect might have occurred after a unit was
dropped or suffered a similar accident,
3. if malfunctions occur.
In any case the units must be repaired by skilled
personnel.
G
Never pull the mains cable for disconnecting the
mains plug from the socket, always seize the plug.
G
For cleaning only use a dry, soft cloth; never use
water or chemicals.
G
No guarantee claims for the units and no liability
for any resulting personal damage or material
damage will be accepted if the units are used for
other purposes than originally intended, if they are
not correctly connected or operated, or if they are
not repaired in an expert way. Likewise, no liability
will be accepted for data loss caused by operating
errors or by a defect and for consequential dam-
age of this data loss.
3 Applications
The digital video recorders DMR-604, DMR-608 and
DMR-616 have been specially designed for applica-
tions in video surveillance systems. Recordings of
up to 4 (DMR-604), 8 (DMR-608) or 16 (DMR-616)
camera signals will be made on one or two hard
disks of 1 TB max. each according to the highly effi-
cient H.264 compression procedure.
The features of the recorders include, among others:
– 3 image resolutions and 5 image qualities
– audio recording for all channels
– recordings triggered via time control or events
(external alarm signal, internal motion detector,
signal loss)
– image corrections to be adjusted separately for
each camera channel
– video motion detector to be configured differently
for each camera channel
– 8-level password protection against unauthorized
operation
– 1 video output and 1 VGA output, 1 audio output,
1 video output and 1 audio output for additional
monitor (DMR-608 and DMR-616 only)
– camera signals to be reproduced individually as a
full image or simultaneously as a split-screen view
– video system to be selected: PAL / NTSC
– easy operation via USB mouse possible
– 4 (DMR-604), 8 (DMR-608) or 16 (DMR-616)
alarm inputs, 1 alarm output
If the units are to be put out of operation
definitively, take them to a local recycling
plant for a disposal which will not be harm-
ful to the environment.
WARNING The power supply unit uses danger-
ous mains voltage. Leave servicing to
skilled personnel only. Inexpert han-
dling or modification of the unit may
result in electric shock.
⑦
25-pole D-Sub jack “AUDIO”
⑥
25-pole D-Sub jack “IO”
⑤