BA FU40knx Anwendungsprogramm HM; DE,GB - 23005 - ED – V09
INSTRUCTION MANUAL ENGLISH PAGE 1 / 3
ENGLISH
Application program
„FU 40.00 knx
Usage: Radio receiver GPS for KNX FU 40.00 knx
Usage:
The “radio receiver GPS-time - KNX” can send the following data to the KNX bus respectively has the
following functionality: Time standard / Geographical position / The course of the angle of solar radiation
during the day / Sunrise and sunset times / Lux value / Temperature value / Time switch standard / Time
switch astro / Time switch astro plus / Light control / Temperature control
Please note:
During polar nights and days in the polar region the values of the sun angle are fixed as follows:
=> Elevation angle =
=> Azimuth = Northern Hemisphere Azimuth South / Southern Hemisphere Azimuth North
Technical data: Radio receiver GPS for KNX FU 40.00 knx
Power Supply:
via KNX bus voltage (nominal voltage 29V)
Bus current:
approx. 10 mA
Bus system:
KNX
Type of protection:
IP 54 (DIN EN 60529)
Permitted ambient temp.:
-30°C … 55°C
Specifications // Compliance:
EN 60730 // CE
Housing:
self-extinguishing thermoplast
Assembly:
wall mounting with mounting bracket
Type of connection:
KNX bus terminal
Rights to technical amendments reserved
Application program
Manufacturer:
Hugo Müller GmbH & Co KG
Program name:
FU 40.00 knx
Communication objects
Number
Name
Object Function
Data Type
0
Sends current date to bus
Send
11.001 date
1
Sends current time to bus
Send
10.001 time of day
3
Bus request to send date and time
Receive
1.017 1-bit
4
Send state of FU 40.00 (0=OK, 1=not OK)
Send
1.005 1-bit
5
Send announcement DST change, 1(True)=summer, 0(False)=winter
Send
1.002 1-bit
6
Send longitude to bus
Send
14.007 angle (degree)
7
Send latitude to bus
Send
14.007 angle (degree)
8
Bus request to send GPS coordinates
Receive
1.017 1-bit
9
Send sun azimuth (east=90°, south=180°) 4 byte
Send
14.007 angle (degree)
10
Send sun azimuth (east=90°, south=180°) 2 byte
Send
9.* 2-byte float value
13
Send sun elevation 4 byte
Send
14.007 angle (degree)
14
Send sun elevation 2 byte
Send
9.* 2-byte float value
15
Bus request to send sun elevation
Receive
1.017 1-bit
16
Send sunrise time to bus
Send
10.001 time of day
17
Send sunset time to bus
Send
10.001 time of day
18
Bus request to send sunrise/sunset
Receive
1.017 1-bit
19
Send temperature to bus
Send
9.001 temperature (°C)
20
Send light value (lux) to bus
Send
9.004 lux (lux)
21
Bus request to send temperature
Receive
1.017 1-bit
22
Bus request to send light value (lux)
Receive
1.017 1-bit
23
Send astro
Send
1.001 1-bit
24
Send light above/below threshold 1
Send
1.001 1-bit
25
Send light above/below threshold 2
Send
1.001 1-bit
26
Send temperature above/below setpoint
Send
1.001 1-bit
27
Send scene light above/below threshold 1
Send
17.001 scene number
28
Send scene light above/below threshold 2
Send
17.001 scene number
29
Send scene temperature above/below setpoint
Send
17.001 scene number
30
Send astro plus scene
Send
17.001 scene number
31
Send astro scene
Send
17.001 scene number
32
Send astro plus
Send
1.001 1-bit
33
Send standard time switch
Send
1.001 1-bit
34
Receive date from bus
Receive
11.001 date
35
Receive time from bus
Receive
10.001 time of day
36
Receive temperature from bus
Receive
9.001 temperature (°C)
37
Receive light value (lux) from bus
Receive
9.004 lux (lux)
38
Receive latitude from bus
Receive
14.007 angle (degree)
39
Receive longitude from bus
Receive
14.007 angle (degree)
40*
Blocking object light control threshold 1
Receive
1.003 enable
41*
Blocking object light control threshold 2
Receive
1.003 enable
42*
Blocking object temperature control
Receive
1.003 enable
* Functions available in ETS application program FU 40.00 knx Version 4.0, only in combination with hardware manufactured in CW16/2017 or later.
4

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Muller FU 40.00 knx wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Andere Handbücher von Muller FU 40.00 knx

Muller FU 40.00 knx Bedienungsanleitung - Deutsch, Englisch - 2 seiten