602911
9
Zoom out
Zoom in
Vorherige Seite
1/146
Nächste Seite
ENGLISH
FRANÇAISDEUTSCHNEDERLANDSESPAÑOL
ITALIANO
PORTUGUÊS
SVENSKA
9
Operation
8 The 12V TRIGGER IN and OUT connectors are 3.5mm monotype
miniature phone jacks, with the centre pin of each serving respectively
as a 12V signal sensor and 12V signal driver. We recommend that you
use a good quality cable with shield when attaching the 3.5mm
monotype plugs so as to prevent false triggering of the amplifier due
to electro-magnetic interference from nearby electronic equipment.
The 12V-IN TRIGGER allows you to have an external 12V signal turn
on the NAD CI-series amplifier from standby. This 12V signal must be
a continuous 12V signal in order to keep the amplifier in the on state.
Once you remove the 12V signal the amplifier will return to standby.
The 12V-OUT TRIGGER allows you to control other products with a
12V sensor, by the NAD CI-series amplifier. The 12V-OUT TRIGGER
is constantly present when the NAD CI-series amplifier is in the on
state, and absent when in standby or VACATION state.
NOTES
Check the specifications of the trigger input terminal on the other
components to ensure these are compatible with the NAD CI-series
amplifiers.
All 12V-TRIGGER inputs and outputs on other NAD components
with a 12V-TRIGGER feature are fully compatible with the NAD
CI–series amplifier’s IN/OUT 12V-TRIGGER.
Before making any connections to any 12V-TRIGGER input or output,
make sure all components are disconnected from the AC mains.
If in doubt over the connections, installation and/or operation of the
IN/OUT 12V-TRIGGER connections consult your NAD dealer or sales
representative.
Failure to observe the above may result in damage to the NAD CI-
series amplifier and/or any ancillary components attached to it.
9 There is one set of speaker terminals per amplifier channel. They are
marked “+” and “-” to indicate their polarity.
10 There are two discrete-types of AC-power cords. Refer to figures
below for the type that relates to your NAD CI-series amplifier:
Before connecting the AC-power cord to a live wall socket insure that
all inputs/outputs are connected first. Always disconnect the AC-
power cord plug from the live wall socket first, before disconnecting
any cable from the CI-series amplifier. If you must use an extension
cord, select a heavy-duty cord of the type used for large electrical
appliances, such as an air conditioner AC-extension cord (16 AWG).
We strongly recommend that you not connect the amplifier’s mains
cable to the accessory AC outlets on a preamplifier. Such convenience
outlets are not designed to supply the high-power levels that the NAD
CI-series amplifier requires.
11 There is a fuse holder nearby or next to the AC-line cord. In the
unlikely event a fuse may need to be replaced, unplug the line cord
form the wall. Then remove all connections from the amplifier. Only
replace the fuse with the same type, size, and specification. Refer to
“SPECIFICATIONS, NAD Models CI 9060 and CI 9120” at the back of
this instruction manual for the correct number, type and size of the
replacement fuse.
CAUTION
Failure to replace the fuse with the correct number, brand
name, and type listed in the “FUSE REPLACEMENT - PLEASE
NOTE CAREFULLY” chart, found in the back of this instruction
manual under section “Fuse Replacement Chart” will eventually
lead to either another blown fuse or amplifier damage.
CI9120_9060 manual (GB) 13/12/02 4:14 pm Page 9
Downloaded from www.Manualslib.com manuals search engine
9

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für NAD CI9060 wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info