780605
28
Zoom out
Zoom in
Vorherige Seite
1/144
Nächste Seite
Product Information
Climate 5000 MS – 6721830160 (2020/12)
28
The outdoor units are designed to be combined with any of the following
types:
Table 3 Types of indoor units
2.3 Recommended combinations of appliances
The tables from page 138 show the options for combining indoor units
with one outdoor unit respectively. If possible, reserve the biggest
connection for the biggest indoor unit. If not all connections are used,
any distribution among the connections can be used.
The power designations of the outdoor and indoor units are stated in
British thermal units (BTU) in the tables. Table 4 shows the conversion to
kW.
Table 4 Conversion of kBTU/h to kW
Example: Climate 5000 MS 21 OUE + 2 × CL...W/CAS/DCT
Table 5 Climate 5000 MS 21 OUE+ 2 × CL...W/CAS/DCT
Table 5 show the options for combining 2 indoor units in total with
one outdoor unit Climate 5000 MS 21 OUE:
A...C Connection A to C at the outdoor unit
PA+...+PCTotal output of all connected indoor units
PA ... PCOutput of indoor unit at connection A to C
2.4 Scope of delivery
Depending on the make up of the system, the supplied appliances may
vary. The scope of delivery of the possible appliances is shown in Fig. 1.
The appliances are shown as an example and deviations are possible.
Outdoor unit (A):
[1] Outdoor unit (filled with refrigerant)
[2] Drainage elbow with gasket (for outdoor unit with floor or wall
mounting bracket)
[3] Set of printed documents for product documentation
[4] Magnetic ring (number depends on appliance type)
[5] Adapter for pipe connections (depending on appliance type)
Table 6 Adaptor and magnet rings included in the delivery
Wall-mounted indoor unit (B):
[1] Indoor unit for wall-mounted installation (filled with nitrogen)
[2] Remote control with batteries
[3] Air filter
[4] Fixing materials (5 screws and 5 wall plugs)
[5] 5-wire communication cable (optional accessory)
[6] Set of printed documents for product documentation
Cassette indoor unit (C):
[1] Indoor unit for ceiling-mounted installation (filled with nitrogen)
[2] Remote control with batteries
[3] Fixing materials
[4] Set of printed documents for product documentation
Built-in ducted indoor unit (D):
[1] Indoor unit for ceiling-mounted installation (filled with nitrogen)
[2] Remote control with batteries
[3] Fixing materials
[4] Set of printed documents for product documentation
2.5 Product dimensions and minimum clearances
2.5.1 Indoor unit and outdoor unit
Outdoor unit
Figures 2 to 3.
Wall-mounted indoor unit
Fig. 14.
Cassette indoor unit
Figures 31 to 29.
[1] Refrigerant pipes
[2] pipe for drainage
Built-in ducted indoor unit
Figures 39 to 40.
[1] Connection for fresh air duct
[2] Air inlet
[3] Air filter/air outlet
[4] Air filter/air outlet (following modification)
[5] Electric control box
2.5.2 Refrigerant pipes
Key to Fig. 4:
[1] Gas-side pipe
[2] Liquid-side pipe
[3] Siphon-shaped elbow as oil separator
If the indoor units are positioned lower than the outdoor unit, install a
siphon-shaped elbow on the gas side after no more than 6 m and every
6 m thereafter ( Fig. 4, [1]).
Model designation Unit type
Climate 5000 MS ... OUE Outdoor unit
CL3000i UW ... E /
CL5000i UW ... E
Wall-mounted indoor unit
CL5000...IBW/RAC...IBW Wall-mounted indoor unit
CL5000MS ... DCT Built-in ducted indoor unit
CL5000MS ... CAS Cassette indoor unit
kBTU/h kW
7 2
9 2.6
12 3.5
18 5.3
24 7.0
27 7.9
36 10.6
42 12.3
PA+...+PC [kBTU/h] PA ... PC [kBTU/h]
A B C
14 77–
16 9 7
... ... ... ...
Unit type
Climate 5000 MS ...
Adapter diameter in
[mm]
Number of magnet
rings
14 OUE 7
18 OUE 6
21 OUE 1 × Ø 9.53 Ø 12.7 7
27 OUE 1 × Ø 9.53 Ø 12.7 8
28 OUE 1 × Ø 12.7 Ø9.53 6
36 OUE 1 × Ø 12.7 Ø9.53 8
42 OUE 1 × Ø 9.53 Ø 12.7
1 × Ø 12.7 Ø9.53
11
28

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Nefit-Bosch Climate 5000 Multi Split wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Andere Handbücher von Nefit-Bosch Climate 5000 Multi Split

Nefit-Bosch Climate 5000 Multi Split Bedienungsanleitung - Deutsch, Englisch, Holländisch, Dänisch, Französisch, Italienisch, Portugiesisch, Spanisch, Polnisch, Türkisch - 64 seiten


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info