44 - English
English
Glossary
Weather dependent (temperature) regulation with room
temperature compensation
This is one of the ways to regulate the temperature in your
house.With this principle, the CH water temperature (and the
intensity of burning of the boiler) is determined, in the first
instance, by the outside temperature and the preset values on the
IRT 30. However, the thermostat also measures the temperature
in the room where it is fitted.The temperature in the room
where the thermostat is fitted is determined by the thermostat
itself.This measured temperature is compared with the set
(desired) temperature.The thermostat can now correct the
preset values to ensure the desired temperature can actually be
reached or maintained.
Firing characteristic
The firing characteristic is a line which shows the temperature of
the CH water at a certain outside temperature.You can set the
firing characteristic with the help of 2 points:
- the desired water temperature at +20 °C outside temperature;
starting point.
- the desired water temperature at -10 °C outside temperature;
end point.