705.259A - 2600 - 04/2002
Min./Max. settings
10 / 25
YES / NO
RR / WD / WD+RTC
1 / 2 / 3 / 4 / N / A
10 / 90
10 / 90
0 / 10
0 / 120
0 / 120
1 / 2 / 3
-99 / 99
SLO / FAST
ON / OFF / AUTO
ON / OFF / AUTO
RR / WD+RTC
21 °C
19 °C
21 °C
ECO
21 °C
ECO
Your settings
(by installer)
(refer to paragraph 6.2)
(refer to paragraph 7.2)
(refer to paragraph 8.1)
(refer to paragraph 4.6)
(refer to paragraph 4.5)
CV menu
ECO-temperature
Advanced heat-up
Kind of temperatur regelation
Installation type
Starting point of the firing characteristic
Endpoint of the firing characteristic
Room influence
Minimum CH water temperature
Hot water menu
Advanced heat water heat-up
Hot water stop delay
Configuration settings
PID number
Correction of the clock speed
Slow temperature rise
Other settings
Hot water
Heating
Standard clock
Monday to Friday 7.00
9.00
17.00
23.00
Saturday and Sunday 8.00
23.00
Settings of the IRT 30
Standard setting
16 °C
YES
RR
N/A
Refer to Table A
10 °C
30 min.
30 min.
1
0
FAST
ON
ON
WD
+1
-1
+1
-4
+1
-4
Table A Standard settings for different types of installation
Installation Type Starting point End point Room influence
1. Radiators 20 °C 75 °C 6
2. Convectors 40 °C 90 °C 8
3. Thermostatic radiator valves in the living room 30 °C 80 °C 0
4. Only floor heating (no radiators or convectors) 20 °C 50 °C 4