18
EN
The on/off indicator (3), the temperature
indicator (5) and the temperature display (6)
will flash to show that the steam generator (2)
is switched off automatically. To switch on the
steam generator (2), lift and gently shake the
iron or press one of the buttons on the control
panel.
Cleaning and maintenance
Before you proceed, we need you to pay
attention to the following notes:
- Before cleaning or maintenance, remove
the mains plug from the wall socket and
wait until the appliance has cooled down.
- Do not immerse the appliance in water or
any other liquids.
Before you proceed, we would like you to
focus your attention on the following notes:
- Do not use aggressive or abrasive cleaning
agents to clean the appliance.
- Do not use sharp objects to clean the
appliance.
Regularly check the appliance for possible •
damage.
Regularly check the water reservoir for •
possible leakage.
Clean the appliance after each use:•
- Empty the water reservoir by draining
the water through the water drain point
into a sink.
- Remove limescale and other
contaminants from the soleplate with a
damp cloth and a non-abrasive cleaning
agent.
- Clean the housing of the iron with
a soft, damp cloth.
- Clean the housing of the steam
generator with a soft, damp cloth.
Replacing the anti-scaling cartridge
(fig. A & E)
The anti-scaling cartridge (25) must be replaced
when the replacement indicator (11) flashes.
Before you proceed, we need you to pay
attention to the following notes:
- Do not use the appliance without the
anti-scaling cartridge (25).
- When the anti-scaling cartridge (25) must
be replaced, you can still use the appliance
for your ironing purposes. Only use distilled
water in the water reservoir (19) when the
anti-scaling cartridge (25) must be
replaced. Do not use tap water in the
water reservoir (19) when the anti-scaling
cartridge (25) must be replaced.
Press the release button (23) to remove the •
water reservoir (19) from the appliance.
Remove the old anti-scaling cartridge (25) •
from the cartridge compartment (26).
If necessary, use kitchen paper to dry the •
cartridge compartment (26).
Place the new anti-scaling cartridge (25) •
into the cartridge compartment (26).
Place the water reservoir (19) into the •
appliance until the release button (23)
clicks into place.
While the replacement indicator (11) •
flashes, keep the on/off button (3) pressed
for 5 seconds to reset the anti-scaling
system. The replacement indicator (11)
goes off.
Rinsing out the boiler of the steam
generator (fig. A & F)
The steam generator (2) must be rinsed out
every month or after every 10 uses.
Before you proceed, we would like you to
focus your attention on the following notes:
- Before rinsing out the boiler of the steam
generator (2), remove the water reservoir
(19).
- Before opening the water drain point (21),
allow the steam generator (2) to cool
down for two hours.
Shake the steam generator (2) for a few •
seconds.
Place the steam generator (2) on its side so •
that the water drain point (21) points
upward.
Remove the cover (27) and loosen the •
screw (28).
Fill the boiler through the water drain •
point (21) with water (300 ml).